ARIS-Campaign: Intercomparison of three ground based 22 GHz radiometers for middle atmospheric water vapor at the Zugspitze in winter 2009

Straub, Corinne; Murk, Axel; Kämpfer, Niklaus; Golchert, Sven H.W.; Hochschild, Gerd; Hallgren, Kristofer; Hartogh, Paul (2011). ARIS-Campaign: Intercomparison of three ground based 22 GHz radiometers for middle atmospheric water vapor at the Zugspitze in winter 2009. Atmospheric Measurement Techniques (AMT), 4(9), pp. 1979-1994. Göttingen: Copernicus Publications 10.5194/amt-4-1979-2011

[img]
Preview
Text
amt-4-1979-2011.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (1MB) | Preview

This paper presents the Alpine Radiometer Intercomparison at the Schneefernerhaus (ARIS), which took place in winter 2009 at the high altitude station at the Zugspitze, Germany (47.42° N, 10.98° E, 2650 m). This campaign was the first direct intercomparison between three new ground based 22 GHz water vapor radiometers for middle atmospheric profiling with the following instruments participating: MIRA 5 (Karlsruhe Institute of Technology), cWASPAM3 (Max Planck Institute for Solar System Research, Katlenburg-Lindau) and MIAWARA-C (Institute of Applied Physics, University of Bern). Even though the three radiometers all measure middle atmospheric water vapor using the same rotational transition line and similar fundamental set-ups, there are major differences between the front ends, the back ends, the calibration concepts and the profile retrieval. The spectrum comparison shows that all three radiometers measure spectra without severe baseline artifacts and that the measurements are in good general agreement. The measurement noise shows good agreement to the values theoretically expected from the radiometer noise formula. At the same time the comparison of the noise levels shows that there is room for instrumental and calibration improvement, emphasizing the importance of low elevation angles for the observation, a low receiver noise temperature and an efficient calibration scheme.

The comparisons of the retrieved profiles show that the agreement between the profiles of MIAWARA-C and cWASPAM3 with the ones of MLS is better than 0.3 ppmv (6%) at all altitudes. MIRA 5 has a dry bias of approximately 0.5 ppm (8%) below 0.1 hPa with respect to all other instruments. The profiles of cWASPAM3 and MIAWARA-C could not be directly compared because the vertical region of overlap was too small. The comparison of the time series at different altitude levels show a similar evolution of the H2O volume mixing ratio (VMR) for the ground based instruments as well as the space borne sensor MLS.

Item Type:

Journal Article (Original Article)

Division/Institute:

08 Faculty of Science > Institute of Applied Physics

UniBE Contributor:

Straub, Corinne, Murk, Axel, Kämpfer, Niklaus

Subjects:

600 Technology > 620 Engineering

ISSN:

1867-1381

Publisher:

Copernicus Publications

Language:

English

Submitter:

Factscience Import

Date Deposited:

04 Oct 2013 14:28

Last Modified:

05 Dec 2022 14:08

Publisher DOI:

10.5194/amt-4-1979-2011

Web of Science ID:

000295367700018

BORIS DOI:

10.7892/boris.10165

URI:

https://boris.unibe.ch/id/eprint/10165 (FactScience: 216013)

Actions (login required)

Edit item Edit item
Provide Feedback