Functional evaluation of transplanted kidneys with diffusion-weighted and BOLD MR imaging: initial experience

Thoeny, Harriet C; Zumstein, Dominik; Simon-Zoula, Sonja; Eisenberger, Ute; De Keyzer, Frederik; Hofmann, Lucie; Vock, Peter; Boesch, Chris; Frey, Felix J; Vermathen, Peter (2006). Functional evaluation of transplanted kidneys with diffusion-weighted and BOLD MR imaging: initial experience. Radiology, 241(3), pp. 812-21. Oak Brook, Ill.: Radiological Society of North America RSNA 10.1148/radiol.2413060103

Full text not available from this repository. (Request a copy)

PURPOSE: To prospectively evaluate feasibility and reproducibility of diffusion-weighted (DW) and blood oxygenation level-dependent (BOLD) magnetic resonance (MR) imaging in patients with renal allografts, as compared with these features in healthy volunteers with native kidneys. MATERIALS AND METHODS: The local ethics committee approved the study protocol; patients provided written informed consent. Fifteen patients with a renal allograft and in stable condition (nine men, six women; age range, 20-67 years) and 15 age- and sex-matched healthy volunteers underwent DW and BOLD MR imaging. Seven patients with renal allografts were examined twice to assess reproducibility of results. DW MR imaging yielded a total apparent diffusion coefficient including diffusion and microperfusion (ADC(tot)), as well as an ADC reflecting predominantly pure diffusion (ADC(D)) and the perfusion fraction. R2* of BOLD MR imaging enabled the estimation of renal oxygenation. Statistical analysis was performed, and analysis of variance was used for repeated measurements. Coefficients of variation between and within subjects were calculated to assess reproducibility. RESULTS: In patients, ADC(tot), ADC(D), and perfusion fraction were similar in the cortex and medulla. In volunteers, values in the medulla were similar to those in the cortex and medulla of patients; however, values in the cortex were higher than those in the medulla (P < .05). Medullary R2* was higher than cortical R2* in patients (12.9 sec(-1) +/- 2.1 [standard deviation] vs 11.0 sec(-1) +/- 0.6, P < .007) and volunteers (15.3 sec(-1) +/- 1.1 vs 11.5 sec(-1) +/- 0.5, P < .0001). However, medullary R2* was lower in patients than in volunteers (P < .004). Increased medullary R2* was paralleled by decreased diffusion in patients with allografts. A low coefficient of variation in the cortex and medulla within subjects was obtained for ADC(tot), ADC(D), and R2* (<5.2%), while coefficient of variation within subjects was higher for perfusion fraction (medulla, 15.1%; cortex, 8.6%). Diffusion and perfusion indexes correlated significantly with serum creatinine concentrations. CONCLUSION: DW and BOLD MR imaging are feasible and reproducible in patients with renal allografts.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Dermatology, Urology, Rheumatology, Nephrology, Osteoporosis (DURN) > Clinic of Nephrology and Hypertension
04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic, Interventional and Paediatric Radiology
04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic, Interventional and Paediatric Radiology > DCR Magnetic Resonance Spectroscopy and Methodology (AMSM)

UniBE Contributor:

Eisenberger, Ute, Hofmann, Lucie, Vock, Peter, Boesch, Christoph Hans, Frey, Felix (B), Vermathen, Peter

ISSN:

0033-8419

ISBN:

17114628

Publisher:

Radiological Society of North America RSNA

Submitter:

Lucie Hofmann

Date Deposited:

04 Oct 2013 14:47

Last Modified:

29 Mar 2023 23:32

Publisher DOI:

10.1148/radiol.2413060103

PubMed ID:

17114628

Web of Science ID:

000242282900023

URI:

https://boris.unibe.ch/id/eprint/19773 (FactScience: 2716)

Actions (login required)

Edit item Edit item
Provide Feedback