The influence of BMP-2 and its mode of delivery on the osteoconductivity of implant surfaces during the early phase of osseointegration

Liu, Yuelian; Enggist, Lukas; Küffer, Alexander Friedrich; Buser, Daniel; Hunziker, Ernst Bruno (2007). The influence of BMP-2 and its mode of delivery on the osteoconductivity of implant surfaces during the early phase of osseointegration. Biomaterials, 28(16), pp. 2677-2686. Oxford: Elsevier 10.1016/j.biomaterials.2007.02.003

[img] Text
23151.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (804kB) | Request a copy

Osteogenic agents, such as bone morphogenetic protein-2 (BMP-2), can stimulate the degradation as well as the formation of bone. Hence, they could impair the osteoconductivity of functionalized implant surfaces. We assessed the effects of BMP-2 and its mode of delivery on the osteoconductivity of dental implants with either a naked titanium surface or a calcium-phosphate-coated one. The naked titanium surface bore adsorbed BMP-2, whilst the coated one bore incorporated, adsorbed, or incorporated and adsorbed BMP-2. The implants were inserted into the maxillae of adult miniature pigs. The volume of bone deposited within a defined "osteoconductive" (peri-implant) space, and bone coverage of the implant surface delimiting this space, were estimated morphometrically 1-3 weeks later. After 3 weeks, the volume of bone deposited within the osteoconductive space was highest for coated and uncoated implants bearing no BMP-2, followed by coated implants bearing incorporated BMP-2; it was lowest for coated implants bearing only adsorbed BMP-2. Bone-interface coverage was highest for coated implants bearing no BMP-2, followed by coated implants bearing either incorporated, or incorporated and adsorbed BMP-2; it was lowest for uncoated implants bearing adsorbed BMP-2. Hence, the osteoconductivity of implant surfaces can be significantly modulated by BMP-2 and its mode of delivery.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Pre-clinic Human Medicine > BioMedical Research (DBMR) > DBMR Forschung Mu35 > Forschungsgruppe Orthopädische Chirurgie
04 Faculty of Medicine > Pre-clinic Human Medicine > BioMedical Research (DBMR) > DBMR Forschung Mu35 > Forschungsgruppe Orthopädische Chirurgie

04 Faculty of Medicine > Department of Orthopaedic, Plastic and Hand Surgery (DOPH) > Clinic of Orthopaedic Surgery
04 Faculty of Medicine > School of Dental Medicine > Department of Oral Surgery and Stomatology

UniBE Contributor:

Liu, Yuelian, Enggist, Lukas, Küffer, Alexander Friedrich, Buser, Daniel Albin, Hunziker, Ernst Bruno

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0142-9612

Publisher:

Elsevier

Language:

English

Submitter:

Eveline Carmen Schuler

Date Deposited:

04 Oct 2013 14:54

Last Modified:

02 Mar 2023 23:22

Publisher DOI:

10.1016/j.biomaterials.2007.02.003

PubMed ID:

17321590

Web of Science ID:

000245691900015

BORIS DOI:

10.7892/boris.23151

URI:

https://boris.unibe.ch/id/eprint/23151 (FactScience: 39941)

Actions (login required)

Edit item Edit item
Provide Feedback