Pelvic radiography in ATLS algorithms: A diminishing role?

Hilty, MP; Behrendt, I; Benneker, LM; Martinolli, L; Stoupis, C; Buggy, DJ; Zimmermann, H; Exadaktylos, AK (2008). Pelvic radiography in ATLS algorithms: A diminishing role? World journal of emergency surgery, 3, p. 11. London: BioMed Central 10.1186/1749-7922-3-11

[img]
Preview
Text
3.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (220kB) | Preview

ABSTRACT: BACKGROUND: Pelvic x-ray is a routine part of the primary survey of polytraumatized patients according to Advanced Trauma Life Support (ATLS) guidelines. However, pelvic CT is the gold standard imaging technique in the diagnosis of pelvic fractures. This study was conducted to confirm the safety of a modified ATLS algorithm omitting pelvic x-ray in hemodynamically stable polytraumatized patients with clinically stable pelvis in favour of later pelvic examination by CT scan. METHODS: We conducted a retrospective analysis of all polytraumatized patients in our emergency room between 01.07.2004 and 31.01.2006. Inclusion criteria were blunt abdominal trauma, initial hemodynamic stability and a stable pelvis on clinical examination. We excluded patients requiring immediate intervention because of hemodynamic instability. RESULTS: We reviewed the records of n = 452 polytraumatized patients, of which n = 91 fulfilled inclusion criteria (56% male, mean age = 45 years). The mechanism of trauma included 43% road traffic accidents, 47% falls. In 68/91 (75%) patients, both a pelvic x-ray and a CT examination were performed; the remainder had only pelvic CT. In 6/68 (9%) patients, pelvic fracture was diagnosed by pelvic x-ray. None of these 6 patients was found having a false positive pelvic x-ray, i.e. there was no fracture on pelvic CT scan. In 3/68 (4%) cases a fracture was missed in the pelvic x-ray, but confirmed on CT (false negative on x-ray). None of the diagnosed fractures needed an immediate therapeutic intervention. 5 (56%) were classified type A fractures, and another 4 (44%) B 2.1 in computed tomography (AO classification). One A 2.1 fracture was found in a clinically stable patient who only received CT scan (1/23). CONCLUSION: While pelvic x-ray is an integral part of ATLS assessment, this retrospective study suggests that in hemodynamically stable patients with clinically stable pevis, its sensitivity is only 67% and it may safely be omitted in favor of a pelvic CT examination if such is planned in adjunct assessment and available. The results support the safety and utility of our modified ATLS algorithm. A randomized controlled trial using the algorithm can safely be conducted to confirm the results.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Intensive Care, Emergency Medicine and Anaesthesiology (DINA) > University Emergency Center
04 Faculty of Medicine > Department of Orthopaedic, Plastic and Hand Surgery (DOPH) > Clinic of Orthopaedic Surgery

UniBE Contributor:

Hilty, Matthias, Benneker, Lorin Michael, Martinolli, Luca, Zimmermann, Heinz (B), Exadaktylos, Aristomenis

ISSN:

1749-7922

ISBN:

18318904

Publisher:

BioMed Central

Language:

English

Submitter:

Factscience Import

Date Deposited:

04 Oct 2013 15:03

Last Modified:

29 Mar 2023 23:33

Publisher DOI:

10.1186/1749-7922-3-11

PubMed ID:

18318904

BORIS DOI:

10.7892/boris.27439

URI:

https://boris.unibe.ch/id/eprint/27439 (FactScience: 107505)

Actions (login required)

Edit item Edit item
Provide Feedback