FACTS: Fully Automatic CT Segmentation of a Hip Joint

Chu, Chengwen; Chen, Cheng; Liu, Li; Zheng, Guoyan (2015). FACTS: Fully Automatic CT Segmentation of a Hip Joint. Annals of biomedical engineering, 43(5), pp. 1247-1259. Springer 10.1007/s10439-014-1176-4

[img]
Preview
Text
art%3A10.1007%2Fs10439-014-1176-4.pdf - Published Version
Available under License Publisher holds Copyright.

Download (3MB) | Preview

Extraction of surface models of a hip joint from CT data is a pre-requisite step for computer assisted diagnosis and planning (CADP) of periacetabular osteotomy (PAO). Most of existing CADP systems are based on manual segmentation, which is time-consuming and hard to achieve reproducible results. In this paper, we present a Fully Automatic CT Segmentation (FACTS) approach to simultaneously extract both pelvic and femoral models. Our approach works by combining fast random forest (RF) regression based landmark detection, multi-atlas based segmentation, with articulated statistical shape model (aSSM) based fitting. The two fundamental contributions of our approach are: (1) an improved fast Gaussian transform (IFGT) is used within the RF regression framework for a fast and accurate landmark detection, which then allows for a fully automatic initialization of the multi-atlas based segmentation; and (2) aSSM based fitting is used to preserve hip joint structure and to avoid penetration between the pelvic and femoral models. Taking manual segmentation as the ground truth, we evaluated the present approach on 30 hip CT images (60 hips) with a 6-fold cross validation. When the present approach was compared to manual segmentation, a mean segmentation accuracy of 0.40, 0.36, and 0.36 mm was found for the pelvis, the left proximal femur, and the right proximal femur, respectively. When the models derived from both segmentations were used to compute the PAO diagnosis parameters, a difference of 2.0 ± 1.5°, 2.1 ± 1.6°, and 3.5 ± 2.3% were found for anteversion, inclination, and acetabular coverage, respectively. The achieved accuracy is regarded as clinically accurate enough for our target applications.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Pre-clinic Human Medicine > Institute for Surgical Technology & Biomechanics ISTB [discontinued]

UniBE Contributor:

Chu, Chengwen, Chen, Cheng, Zheng, Guoyan

Subjects:

500 Science > 570 Life sciences; biology
600 Technology > 610 Medicine & health
600 Technology > 620 Engineering

ISSN:

0090-6964

Publisher:

Springer

Language:

English

Submitter:

Guoyan Zheng

Date Deposited:

01 May 2015 16:31

Last Modified:

05 Dec 2022 14:46

Publisher DOI:

10.1007/s10439-014-1176-4

BORIS DOI:

10.7892/boris.67988

URI:

https://boris.unibe.ch/id/eprint/67988

Actions (login required)

Edit item Edit item
Provide Feedback