Evaluation of a Novel Screw Position in a Type III Distal Phalanx Fracture Model: An Ex Vivo Study

Bindler, Dorian; Koch, Christoph; Gendron, Karine; Ferguson, Stephen John; Kaposi, Andras D.; Papp, Miklos; Bodó, Gabor (2015). Evaluation of a Novel Screw Position in a Type III Distal Phalanx Fracture Model: An Ex Vivo Study. Veterinary surgery, 44(7), pp. 829-837. Wiley-Blackwell 10.1111/vsu.12354

[img] Text
Bindler_et_al-2015-Veterinary_Surgery.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (977kB) | Request a copy

OBJECTIVE:

Mechanical evaluation of a novel screw position used for repair in a type III distal phalanx fracture model and assessment of solar canal penetration (SCP).

STUDY DESIGN:

Experimental study.

SAMPLE POPULATION:

Disarticulated equine hooves (n = 24) and 24 isolated distal phalanges.

METHODS:

Hooves/distal phalanges cut in a sagittal plane were repaired with 1 of 2 different cortical screw placements in lag fashion. In group 1 (conventional screw placement), the screw was inserted halfway between the proximal border of the solar canal (SC) and the subchondral bone surface on a line parallel to the dorsal cortex, whereas in group 2, the screw was inserted more palmar/plantar, where a perpendicular line drawn from the group 1 position reached the palmar/plantar cortex. Construct strength was evaluated by 3-point bending to failure. SCP was assessed by CT imaging and macroscopically.

RESULTS:

Screws were significantly longer in group 2 and in forelimbs. Group 2 isolated distal phalanges had a significantly more rigid fixation compared with the conventional screw position (maximum point at failure 31%, bending stiffness 41% higher). Lumen reduction of the SC was observed in 13/52 specimens (all from group 2), of which 9 were forelimbs.

CONCLUSIONS:

More distal screw positioning compared with the conventionally recommended screw position for internal fixation of type III distal phalangeal fractures allows placement of a longer screw and renders a more rigid fracture fixation. The novel screw position, however, carries a higher risk of SCP

Item Type:

Journal Article (Original Article)

Division/Institute:

05 Veterinary Medicine > Department of Clinical Veterinary Medicine (DKV) > ISME Equine Clinic Bern > ISME Equine Clinic, Internal medicine
04 Faculty of Medicine > Pre-clinic Human Medicine > Institute for Surgical Technology & Biomechanics ISTB [discontinued]
05 Veterinary Medicine > Department of Clinical Veterinary Medicine (DKV) > DKV - Clinical Radiology
05 Veterinary Medicine > Department of Clinical Veterinary Medicine (DKV)

UniBE Contributor:

Bindler, Dorian, Koch, Christoph, Gendron, Karine, Ferguson, Stephen John, Bodó, Gabor

Subjects:

600 Technology > 630 Agriculture
500 Science > 570 Life sciences; biology
600 Technology > 610 Medicine & health

ISSN:

0161-3499

Publisher:

Wiley-Blackwell

Language:

English

Submitter:

Andrea Gassmann-Suter

Date Deposited:

23 Feb 2016 16:31

Last Modified:

05 Dec 2022 14:51

Publisher DOI:

10.1111/vsu.12354

PubMed ID:

26147008

BORIS DOI:

10.7892/boris.75827

URI:

https://boris.unibe.ch/id/eprint/75827

Actions (login required)

Edit item Edit item
Provide Feedback