Simultaneous multi-slice readout-segmented echo planar imaging for accelerated diffusion-weighted imaging of the breast

Filli, Lukas; Ghafoor, Soleen; Kenkel, David; Liu, Wei; Weiland, Elisabeth; Andreisek, Gustav; Frauenfelder, Thomas; Runge, Val Murray; Boss, Andreas (2016). Simultaneous multi-slice readout-segmented echo planar imaging for accelerated diffusion-weighted imaging of the breast. European journal of radiology, 85(1), pp. 274-278. Thieme 10.1016/j.ejrad.2015.10.009

[img] Text
1-s2.0-S0720048X15301297-main.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (1MB) | Request a copy

OBJECTIVES

Readout-segmented echo planar imaging (rs-EPI) significantly reduces susceptibility artifacts in diffusion-weighted imaging (DWI) of the breast compared to single-shot EPI but is limited by longer scan times. To compensate for this, we tested a new simultaneous multi-slice (SMS) acquisition for accelerated rs-EPI.

MATERIALS AND METHODS

After approval by the local ethics committee, eight healthy female volunteers (age, 38.9±13.1 years) underwent breast MRI at 3T. Conventional as well as two-fold (2× SMS) and three-fold (3× SMS) slice-accelerated rs-EPI sequences were acquired at b-values of 50 and 800s/mm(2). Two independent readers analyzed the apparent diffusion coefficient (ADC) in fibroglandular breast parenchyma. The signal-to-noise ratio (SNR) was estimated based on the subtraction method. ADC and SNR were compared between sequences by using the Friedman test.

RESULTS

The acquisition time was 4:21min for conventional rs-EPI, 2:35min for 2× SMS rs-EPI and 1:44min for 3× SMS rs-EPI. ADC values were similar in all sequences (mean values 1.62×10(-3)mm(2)/s, p=0.99). Mean SNR was 27.7-29.6, and no significant differences were found among the sequences (p=0.83).

CONCLUSION

SMS rs-EPI yields similar ADC values and SNR compared to conventional rs-EPI at markedly reduced scan time. Thus, SMS excitation increases the clinical applicability of rs-EPI for DWI of the breast.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic, Interventional and Paediatric Radiology

UniBE Contributor:

Runge, Val Murray

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0720-048X

Publisher:

Thieme

Language:

English

Submitter:

Aisha Stefania Mzinga

Date Deposited:

24 May 2016 16:24

Last Modified:

05 Dec 2022 14:52

Publisher DOI:

10.1016/j.ejrad.2015.10.009

PubMed ID:

26547123

Uncontrolled Keywords:

Blipped CAIPIRINHA; Breast; Diffusion-weighted imaging; Readout-segmented echo planar imaging; Simultaneous multi-slice

BORIS DOI:

10.7892/boris.77237

URI:

https://boris.unibe.ch/id/eprint/77237

Actions (login required)

Edit item Edit item