Akarçay, Hidayet Günhan

Up a level
Export as [feed] RSS
Group by: Item Type | No Grouping
Number of items: 12.

Ulrich, Leonie; Held, Kai Gerrit; Jaeger, Michael; Frenz, Martin; Akarçay, Hidayet Günhan (2020). Reliability assessment for blood oxygen saturation levels measured with optoacoustic imaging. Journal of biomedical optics, 25(04), p. 1. SPIE International Society for Optical Engineering 10.1117/1.JBO.25.4.046005

Akarçay, Hidayet Günhan; Hornung, Manes; Jain, Arushi; Frenz, Martin (4 March 2019). Towards the analytical modeling of backscattering polarimetric patterns recorded from multiply scattering systems (Conference Presentation). In: Three-Dimensional and Multidimensional Microscopy: Image Acquisition and Processing XXVI. Proc. SPIE: Vol. 10883 (p. 17). SPIE 10.1117/12.2509366

Ulrich, Leonie; Ahnen, Linda; Akarçay, Hidayet Günhan; Majos, Salvador Sánchez; Jaeger, Michael; Held, Kai Gerrit; Wolf, Martin; Frenz, Martin (2019). Spectral correction for handheld optoacoustic imaging by means of near-infrared optical tomography in reflection mode. Journal of biophotonics, 12(1), e201800112. Wiley-VCH 10.1002/jbio.201800112

Held, Kai Gerrit; Jaeger, Michael; Frenz, Martin; Akarçay, Hidayet Günhan (2016). Spectral correction of OA signals based on multiple irradiation sensing: experimental validation. In: Oraevsky, Alexander A.; Wang, Lihong V. (eds.) Photons Plus Ultrasound: Imaging and Sensing 2016. Proceedings of SPIE: Vol. 9708 (97081E). SPIE 10.1117/12.2214299

Held, Kai Gerrit; Jaeger, Michael; Ricka, Jaroslav; Frenz, Martin; Akarçay, Hidayet Günhan (2016). Multiple irradiation sensing of the optical effective attenuation coefficient for spectral correction in handheld OA imaging. Photoacoustics, 4(2), pp. 70-80. Elsevier 10.1016/j.pacs.2016.05.004

Preisser, Stefan; Held, Kai Gerrit; Akarçay, Hidayet Günhan; Jaeger, Michael; Frenz, Martin (2016). Study of clutter origin in in-vivo epi-optoacoustic imaging of human forearms. Journal of optics, 18(9), 094003. IOP Publishing 10.1088/2040-8978/18/9/094003

Jaeger, Michael; Robinson, Elise; Akarçay, Hidayet Günhan; Frenz, Martin (2015). Full correction for spatially distributed speed-of-sound in echo ultrasound based on measuring aberration delays via transmit beam steering. Physics in medicine and biology, 60(11), pp. 4497-4515. Institute of Physics Publishing IOP 10.1088/0031-9155/60/11/4497

Akarçay, Hidayet Günhan; Hohmann, Ansgar; Kienle, Alwin; Ricka, Jaroslav; Frenz, Martin (2014). Monte Carlo modeling of polarized light propagation: Stokes vs Jones - Part II. Applied optics, 53(31), pp. 7586-7602. Optical Society of America 10.1364/AO.53.007586

Held, Kai Gerrit; Preisser, Stefan; Akarçay, Hidayet Günhan; Peeters, Sara Elisa; Frenz, Martin; Jaeger, Michael (2014). Effect of irradiation distance on image contrast in epi-optoacoustic imaging of human volunteers. Biomedical optics express, 5(11), pp. 3765-3780. Optical Society of America 10.1364/BOE.5.003765

Jaeger, Michael; Gashi, Kujtim; Akarçay, Hidayet Günhan; Held, Gerrit; Peeters, Sara; Petrosyan, Tigran; Preisser, Stefan; Grünig, Michael; Frenz, Martin (2014). Real-time clinical clutter reduction in combined epi-optoacoustic and ultrasound imaging. Photonics & Lasers in Medicine, 3(4), pp. 343-349. De Gruyter 10.1515/plm-2014-0028

Brandes, Arnd; Elmaklizi, Ahmed; Akarçay, Hidayet Günhan; Kienle, Alwin (2014). Modeling the Tight Focusing of Beams in Absorbing Media with Monte Carlo Simulations. Journal of biomedical optics, 19(11), p. 115003. SPIE International Society for Optical Engineering 10.1117/1.JBO.19.11.115003

Akarçay, Hidayet Günhan; Preisser, Stefan; Frenz, Martin; Ricka, Jaro (2012). Determining the optical properties of a gelatin-TiO2 phantom at 780 nm. Biomedical optics express, 3(3), pp. 418-434. Washington, D.C.: Optical Society of America 10.1364/BOE.3.000418

This list was generated on Thu Mar 28 23:31:37 2024 CET.
Provide Feedback