Hinzpeter, R; Boehm, T; Boll, D; Constantin, C; Del Grande, F; Fretz, V; Leschka, S; Ohletz, T; Brönnimann, Michael; Schmidt, S; Treumann, T; Poletti, P-A; Alkadhi, Hatem (2017). Imaging algorithms and CT protocols in trauma patients: survey of Swiss emergency centers. European radiology, 27(5), pp. 1922-1928. Springer 10.1007/s00330-016-4574-1

[img]
Preview
Text
10.1007_s00330-016-4574-1.pdf - Published Version
Available under License Publisher holds Copyright.

Download (523kB) | Preview

OBJECTIVES

To identify imaging algorithms and indications, CT protocols, and radiation doses in polytrauma patients in Swiss trauma centres.

METHODS

An online survey with multiple choice questions and free-text responses was sent to authorized level-I trauma centres in Switzerland.

RESULTS

All centres responded and indicated that they have internal standardized imaging algorithms for polytrauma patients. Nine of 12 centres (75 %) perform whole-body CT (WBCT) after focused assessment with sonography for trauma (FAST) and conventional radiography; 3/12 (25 %) use WBCT for initial imaging. Indications for WBCT were similar across centres being based on trauma mechanisms, vital signs, and presence of multiple injuries. Seven of 12 centres (58 %) perform an arterial and venous phase of the abdomen in split-bolus technique. Six of 12 centres (50 %) use multiphase protocols of the head (n = 3) and abdomen (n = 4), whereas 6/12 (50 %) use single-phase protocols for WBCT. Arm position was on the patient`s body during scanning (3/12, 25 %), alongside the body (2/12, 17 %), above the head (2/12, 17 %), or was changed during scanning (5/12, 42 %). Radiation doses showed large variations across centres ranging from 1268-3988 mGy*cm (DLP) per WBCT.

CONCLUSIONS

Imaging algorithms in polytrauma patients are standardized within, but vary across Swiss trauma centres, similar to the individual WBCT protocols, resulting in large variations in associated radiation doses.

KEY POINTS

• Swiss trauma centres have internal standardized imaging algorithms for trauma patients • Whole-body CT is most commonly used for imaging of trauma patients • CT protocols and radiation doses vary greatly across Swiss trauma centres.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic, Interventional and Paediatric Radiology

UniBE Contributor:

Brönnimann, Michael

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0938-7994

Publisher:

Springer

Language:

English

Submitter:

Nicole Rösch

Date Deposited:

13 Sep 2017 12:31

Last Modified:

05 Dec 2022 15:06

Publisher DOI:

10.1007/s00330-016-4574-1

PubMed ID:

27595837

Uncontrolled Keywords:

Algorithm Computed tomography Imaging Radiation Trauma

BORIS DOI:

10.7892/boris.101439

URI:

https://boris.unibe.ch/id/eprint/101439

Actions (login required)

Edit item Edit item
Provide Feedback