Perlman, Gidon; Praz, Fabien; Puri, Rishi; Ofek, Hadass; Ye, Jian; Philippon, Francois; Carrel, Thierry; Pibarot, Philippe; Attinger, Adrian; Htun, Nay Min; Dvir, Danny; Moss, Robert; Campelo-Parada, Francisco; Bédard, Elisabeth; Reineke, David Christian; Moschovitis, Aris; Lauck, Sandra; Blanke, Philipp; Leipsic, Jonathon; Windecker, Stephan; ... (2017). Transcatheter Tricuspid Valve Repair With a New Transcatheter Coaptation System for the Treatment of Severe Tricuspid Regurgitation: 1-Year Clinical and Echocardiographic Results. JACC. Cardiovascular Interventions, 10(19), pp. 1994-2003. Elsevier 10.1016/j.jcin.2017.06.036
Text
1-s2.0-S1936879817313122-main.pdf - Published Version Restricted to registered users only Available under License Publisher holds Copyright. Download (827kB) |
OBJECTIVES
This study sought to describe the 1-year experience with the transcatheter FORMA system for severe tricuspid regurgitation (TR).
BACKGROUND
Severe TR is associated with significant morbidity and mortality. Novel transcatheter therapies have been recently developed.
METHODS
Eighteen patients underwent device implantation at 3 centers in Canada and Switzerland. Baseline characteristics, procedural, 30-day, and 1-year outcomes were prospectively evaluated using multimodality imaging and hemodynamic and clinical assessments.
RESULTS
Procedural success was achieved in 16 (89%) patients. Unsuccessful procedures were because of right ventricular perforation requiring open surgery and device dislocation. At 1 year there were no deaths, significant arrhythmias, device infections, or dislocations. Thrombus was observed on 1 device at 4 months and there was 1 rehospitalization for heart failure. Among the 14 patients with successful device implantation and 1-year follow-up, 79% were in New York Heart Association functional class I/II (p < 0.001), the average 6-min-walk test increased by 84 m (p = 0.03), and the Kansas City Cardiomyopathy Questionaire heart failure score improved by 18 points (p = 0.02) compared with baseline. Echocardiography showed a reduction of TR from severe in 17 of 18 (94%) patients at baseline to moderate-severe or less in 11 of 16 patients (69%) by 30 days (p = 0.001) and 6 of 13 patients (46%) by 1 year (p = 0.01). The diameters of the tricuspid annulus and the right ventricle were reduced at 1 year (45.7 ± 4.8 mm to 42.1 ± 4.4 mm, p = 0.004; 54 ± 5.3 mm to 49.9 ± 4.3 mm, p = 0.02, respectively).
CONCLUSIONS
Implantation of the FORMA system in high-risk patients with severe TR shows feasibility with a good mid-term safety profile. At 1 year, despite variable success in reducing echocardiographic TR grade, there were significant clinical improvements and reductions in right ventricular dimensions.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology 04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Heart Surgery |
UniBE Contributor: |
Praz, Fabien Daniel, Carrel, Thierry, Reineke, David Christian, Moschovitis, Aris |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
1876-7605 |
Publisher: |
Elsevier |
Language: |
English |
Submitter: |
Daniela Huber |
Date Deposited: |
20 Sep 2017 09:21 |
Last Modified: |
27 Feb 2024 14:28 |
Publisher DOI: |
10.1016/j.jcin.2017.06.036 |
PubMed ID: |
28780036 |
Uncontrolled Keywords: |
transcatheter coaptation system tricuspid regurgitation |
BORIS DOI: |
10.7892/boris.105418 |
URI: |
https://boris.unibe.ch/id/eprint/105418 |