Targeting Moderate and Severe Male Stress Urinary Incontinence With Adjustable Male Slings and the Perineal Artificial Urinary Sphincter: Focus on Perioperative Complications and Device Explantations.

Kretschmer, Alexander; Hüsch, Tanja; Thomsen, Frauke; Kronlachner, Dominik; Obaje, Alice; Anding, Ralf; Pottek, Tobias; Rose, Achim; Olianas, Roberto; Friedl, Alexander; Hübner, Wilhelm; Homberg, Roland; Pfitzenmaier, Jesco; Queissert, Fabian; Naumann, Carsten M; Wotzka, Carola; Hofmann, Torben; Seiler, Roland; Haferkamp, Axel and Bauer, Ricarda M (2017). Targeting Moderate and Severe Male Stress Urinary Incontinence With Adjustable Male Slings and the Perineal Artificial Urinary Sphincter: Focus on Perioperative Complications and Device Explantations. International neurourology journal, 21(2), pp. 109-115. Korean Continence Society 10.5213/inj.1632626.313

[img]
Preview
Text
Seiler_Int Neurourol_Targeting moderate and severe.pdf - Published Version
Available under License Creative Commons: Attribution-Noncommercial (CC-BY-NC).

Download (325kB) | Preview

PURPOSE

To analyze perioperative complications and postoperative explantation rates for selected readjustable male sling systems and the perineal single-cuff artificial urinary sphincter (AUS) in a large, contemporary, multi-institutional patient cohort.

METHODS

Two hundred eighty-two male patients who underwent implantation between 2010 and 2012 in 13 participating institutions were included in the study (n=127 adjustable male sling [n=95 Argus classic, n=32 Argus T], n=155 AUS). Perioperative characteristics and postoperative complications were analyzed. The explantation rates of the respective devices were assessed using the Fisher exact test and the Mann-Whitney U-test. A Kaplan-Meier curve was generated. Potential features associated with device explantation were analyzed using a multiple logistic regression model (P<0.05).

RESULTS

We found significantly increased intraoperative complication rates after adjustable male sling implantation (15.9% [adjustable male sling] vs. 4.2% [AUS], P=0.003). The most frequent intraoperative complication was bladder perforation (n=17). Postoperative infection rates did not vary significantly between the respective devices (P=0.378). Device explantation rates were significantly higher after AUS implantation (9.7% [adjustable male sling] vs. 21.5% [AUS], P=0.030). In multivariate analysis, postoperative infection was a strong independent predictor of decreased device survival (odds ratio, 6.556; P=0.001).

CONCLUSIONS

Complication profiles vary between adjustable male slings and AUS. Explantation rates are lower after adjustable male sling implantation. Any kind of postoperative infections are independent predictors of decreased device survival. There is no significant effect of the experience of the implanting institution on device survival.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Dermatology, Urology, Rheumatology, Nephrology, Osteoporosis (DURN) > Clinic of Urology

UniBE Contributor:

Seiler-Blarer, Roland

Subjects:

600 Technology > 610 Medicine & health

ISSN:

2093-4777

Publisher:

Korean Continence Society

Language:

English

Submitter:

Laetitia Hayoz

Date Deposited:

28 Feb 2018 16:28

Last Modified:

02 Mar 2023 23:30

Publisher DOI:

10.5213/inj.1632626.313

PubMed ID:

28673058

Uncontrolled Keywords:

Complications Urinary Incontinence, Stress Urinary Sphincter, Artificial

BORIS DOI:

10.7892/boris.108763

URI:

https://boris.unibe.ch/id/eprint/108763

Actions (login required)

Edit item Edit item