Gillmann, Clarissa; Lomax, Antony J; Weber, Damien Charles; Jäkel, Oliver; Karger, Christian P (2018). Dose-response curves for MRI-detected radiation-induced temporal lobe reactions in patients after proton and carbon ion therapy: Does the same RBE-weighted dose lead to the same biological effect? Radiotherapy and oncology, 128(1), pp. 109-114. Elsevier 10.1016/j.radonc.2018.01.018

[img] Text
1-s2.0-S0167814018300446-main.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (736kB)

PURPOSE

To derive the dose-response curve for temporal lobe reactions (TLRs) after proton therapy and to compare the resulting relative biological effectiveness (RBE)-weighted tolerance doses based on an RBE of 1.1 with published values for carbon ions, which were calculated by the two versions of the local effect model (LEM I or IV).

METHODS AND MATERIALS

62 patients treated with protons for skull base tumors were analyzed for TLRs using magnetic resonance imaging. Within the mean follow-up time of 38 months, TLRs were observed in six patients. Dose-response curves based on the RBE-weighted maximum dose, excluding the 1 cm-volume with the highest dose, were derived and compared to previously published dose-response curves for carbon ions, which were obtained using LEM I or IV, respectively.

RESULTS

The dose-response curves for protons and LEM I were found to be almost identical while the curve of LEM IV was shifted toward higher doses. The resulting tolerance doses at the 5% effect level were 68.2, 68.6and 78.3Gy (RBE), respectively.

CONCLUSIONS

The RBE-weighted dose prescription for protons leads to the same RBE-weighted dose-response curve for TLR as the one for LEM I-based carbon ions, while LEM IV predicts clinically significant higher tolerance doses.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Haematology, Oncology, Infectious Diseases, Laboratory Medicine and Hospital Pharmacy (DOLS) > Clinic of Radiation Oncology

UniBE Contributor:

Weber, Damien Charles

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0167-8140

Publisher:

Elsevier

Language:

English

Submitter:

Beatrice Scheidegger

Date Deposited:

21 Jun 2018 09:47

Last Modified:

05 Dec 2022 15:11

Publisher DOI:

10.1016/j.radonc.2018.01.018

PubMed ID:

29459152

Uncontrolled Keywords:

Local effect model Proton and carbon ion radiotherapy Relative biological effectiveness Temporal lobe tolerance dose

BORIS DOI:

10.7892/boris.112238

URI:

https://boris.unibe.ch/id/eprint/112238

Actions (login required)

Edit item Edit item
Provide Feedback