In Vitro Biomechanical Comparison of Four Different Ventral Surgical Procedures on the Canine Fourth-Fifth Cervical Vertebral Motion Unit.

Hermann, Andreas; Voumard, Benjamin; Waschk, Maja Alice; Hettlich, Bianca Felicitas; Forterre, Franck (2018). In Vitro Biomechanical Comparison of Four Different Ventral Surgical Procedures on the Canine Fourth-Fifth Cervical Vertebral Motion Unit. Veterinary and comparative orthopaedics and traumatology, 31(6), pp. 413-421. Thieme 10.1055/s-0038-1667200

Full text not available from this repository.

INTRODUCTION

Biomechanical properties of four different ventral surgical procedures at the canine fourth-fifth cervical (C4-C5) vertebral motion unit (VMU) were assessed and compared with the intact C4-C5 VMU.

MATERIALS AND METHODS

The third-sixth cervical vertebral column from 24 skeletally mature Beagle cadavers were randomly allocated to four groups (standard ventral slot, slanted slot, inverted cone slot and intervertebral disc fenestration). Standardized tests were performed for each specimen in flexion/extension, lateral bending and axial rotation. The specimens were tested intact and after completion of one of the three slots techniques or fenestration. Pre-testing, cadaver specimens were confirmed to be free of disease by computed tomography (CT) examination. Post-testing, dimensions of slots and fenestration were determined based on a second CT examination.

RESULTS

All ventral surgical procedures increased range of motion (ROM) at the C4-C5 VMU compared with intact specimens. The only significant difference in the increase in ROM was observed between slanted slot and fenestration in flexion/extension. The standard ventral slot had a significant higher increase in ROM in extension compared with the other three techniques. The slanted slot had a significant lower increase in ROM in flexion.

DISCUSSION/CONCLUSION

The described ventral slot techniques have similar biomechanical effects on the canine cervical vertebral column. In contrast to the findings of a previous study, the slanted slot and inverted cone slot do not appear to provide a biomechanical benefit compared with standard ventral slot.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Pre-clinic Human Medicine > Institute for Surgical Technology & Biomechanics ISTB [discontinued]
05 Veterinary Medicine > Department of Clinical Veterinary Medicine (DKV) > Small Animal Clinic > Small Animal Clinic, Surgery
05 Veterinary Medicine > Department of Clinical Veterinary Medicine (DKV) > DKV - Clinical Radiology

UniBE Contributor:

Hermann, Andreas, Voumard, Benjamin, Waschk, Maja Alice, Hettlich, Bianca Felicitas, Forterre, Franck

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0932-0814

Publisher:

Thieme

Language:

English

Submitter:

Bianca Felicitas Hettlich

Date Deposited:

07 Dec 2018 16:09

Last Modified:

05 Dec 2022 15:21

Publisher DOI:

10.1055/s-0038-1667200

PubMed ID:

30235472

URI:

https://boris.unibe.ch/id/eprint/122059

Actions (login required)

Edit item Edit item
Provide Feedback