Clinical evaluation of non-surgical cleaning modalities on titanium dental implants during maintenance care: a 1-year follow-up on prosthodontic superstructures.

Schmidt, Kristina Emily; Auschill, Thorsten Mathias; Sculean, Anton; Arweiler, Nicole Birgit (2019). Clinical evaluation of non-surgical cleaning modalities on titanium dental implants during maintenance care: a 1-year follow-up on prosthodontic superstructures. Clinical oral investigations, 23(4), pp. 1921-1930. Springer-Verlag 10.1007/s00784-018-2640-6

[img]
Preview
Text
Schmidt2018_Article_ClinicalEvaluationOfNon-surgic(1).pdf - Published Version
Available under License Publisher holds Copyright.

Download (905kB) | Preview

OBJECTIVES

To investigate tissue health around implants with newly attached superstructures over 12 months of preventive maintenance appointments and instrumentation when necessary.

MATERIAL AND METHODS

In a randomized, split-mouth study 32 implants (8 participants with 4 implants each) received followed-up care every 3 months after superstructure attachment. Implants and superstructures were randomly assigned to four treatment groups and treated if necessary: (1) titanium curettes (TC), (2) stainless steel ultrasonic tip (PS), (3) erythritol air-polishing powder (EP), or (4) rubber cup polishing (CON). Probing depths (PDs), bleeding on probing (BOP), modified gingival (mucosal) bleeding index (GBI) around implants, and full-mouth Plaque Control Record (PCR) were measured every 3 months. Clinical attachment levels (CALs) and height of keratinized mucosa (KM)/gingival margins (GMs) for implants/teeth and PD, BOP, and GBI for teeth were documented at baseline, 6 months, and 12 months. Matrix metalloproteinase 8 (MMP-8) and periopathogens were measured at baseline and 12 months.

RESULTS

Participants exhibited minimal signs of periodontal inflammation with statistically significant PD improvement (3.0 ± 0.2 to 2.8 ± 0.3 mm; p = 0.022) and overall CAL (4.3 ± 0.8 to 4.0 ± 0.7 mm; p = 0.048) after 1 year. Implants showed no statistically significant differences (p > 0.05) between or within groups at baseline or 12 months for any parameter, except MMP-8 decreased significantly for PS (14.50 ± 17.58 to 4.63 ± 7.56 ng; p = 0.044), and after 12 months, PCR showed a significant difference between TC and PS (p = 0.018).

CONCLUSIONS

Treatment was necessary as inflammation was observed around newly placed superstructures within the first year of maintenance care. All tested treatment modalities yielded comparable clinical improvements.

CLINICAL RELEVANCE

Early assessment and diagnosis of mucositis and regular maintenance can promote long-lasting implant health.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Periodontology

UniBE Contributor:

Sculean, Anton

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1432-6981

Publisher:

Springer-Verlag

Language:

English

Submitter:

Doris Burri

Date Deposited:

20 May 2019 17:29

Last Modified:

05 Dec 2022 15:25

Publisher DOI:

10.1007/s00784-018-2640-6

PubMed ID:

30232627

Uncontrolled Keywords:

Biocompatibility Individualized care Maintenance Oral hygiene Titanium dental implants

BORIS DOI:

10.7892/boris.125330

URI:

https://boris.unibe.ch/id/eprint/125330

Actions (login required)

Edit item Edit item
Provide Feedback