Liu, Xinyu; Hoene, Miriam; Yin, Peiyuan; Fritsche, Louise; Plomgaard, Peter; Hansen, Jakob S.; Nakas, Christos T.; Niess, Andreas M.; Hudemann, Jens; Haap, Michael; Mendy, Maimuna; Weigert, Cora; Wang, Xiaolin; Fritsche, Andreas; Peter, Andreas; Häring, Hans-Ulrich; Xu, Guowang; Lehmann, Rainer (2018). Quality Control of Serum and Plasma by Quantification of (4E,14Z)-Sphingadienine-C18-1-Phosphate Uncovers Common Preanalytical Errors During Handling of Whole Blood. Clinical chemistry, 64(5), pp. 810-819. American Association for Clinical Chemistry 10.1373/clinchem.2017.277905

[img] Text
810.full.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (1MB)

BACKGROUND:
Nonadherence to standard operating procedures (SOPs) during handling and processing of whole blood is one of the most frequent causes affecting the quality of serum and plasma. Yet, the quality of blood samples is of the utmost importance for reliable, conclusive research findings, valid diagnostics, and appropriate therapeutic decisions.

METHODS:
UHPLC-MS-driven nontargeted metabolomics was applied to identify biomarkers that reflected time to processing of blood samples, and a targeted UHPLC-MS analysis was used to quantify and validate these biomarkers.

RESULTS:
We found that (4E,14Z)-sphingadienine-C18-1-phosphate (S1P-d18:2) was suitable for the reliable assessment of the pronounced changes in the quality of serum and plasma caused by errors in the phase between collection and centrifugation of whole blood samples. We rigorously validated S1P-d18:2, which included the use of practicality tests on >1400 randomly selected serum and plasma samples that were originally collected during single- and multicenter trials and then stored in 11 biobanks in 3 countries. Neither life-threatening disease states nor strenuous metabolic challenges (i.e., high-intensity exercise) affected the concentration of S1P-d18:2. Cutoff values for sample assessment were defined (plasma, ≤0.085 μg/mL; serum, ≤0.154 μg/mL).

CONCLUSIONS:
Unbiased valid monitoring to check for adherence to SOP-dictated time for processing to plasma or serum and/or time to storage of whole blood at 4 °C is now feasible. This novel quality assessment step could enable scientists to uncover common preanalytical errors, allowing for identification of serum and plasma samples that should be excluded from certain investigations. It should also allow control of samples before long-term storage in biobanks.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Haematology, Oncology, Infectious Diseases, Laboratory Medicine and Hospital Pharmacy (DOLS) > Institute of Clinical Chemistry

UniBE Contributor:

Nakas, Christos T.

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0009-9147

Publisher:

American Association for Clinical Chemistry

Language:

English

Submitter:

Marie-Christine Müller

Date Deposited:

13 Mar 2019 13:26

Last Modified:

05 Dec 2022 15:26

Publisher DOI:

10.1373/clinchem.2017.277905

PubMed ID:

29567661

BORIS DOI:

10.7892/boris.125820

URI:

https://boris.unibe.ch/id/eprint/125820

Actions (login required)

Edit item Edit item
Provide Feedback