Quality difference of neointima following the implantation of everolimus-eluting bioresorbable scaffolds and metallic stents in patients with ST-elevation myocardial infarction: quantitative assessments by light intensity, light attenuation, and backscatter on optical coherence tomography in the TROFI II trial.

Sotomi, Yohei; Onuma, Yoshinobu; Liu, Shengnan; Asano, Taku; Eggermont, Jeroen; Katagiri, Yuki; Cavalcante, Rafael; de Winter, Robbert J; Wykrzykowska, Joanna J; Brugaletta, Salvatore; Räber, Lorenz; Sabaté, Manel; Windecker, Stephan; Dijkstra, Jouke; Serruys, Patrick W (2018). Quality difference of neointima following the implantation of everolimus-eluting bioresorbable scaffolds and metallic stents in patients with ST-elevation myocardial infarction: quantitative assessments by light intensity, light attenuation, and backscatter on optical coherence tomography in the TROFI II trial. EuroIntervention, 14(6), pp. 678-685. Europa Digital & Publishing 10.4244/EIJ-D-17-00884

Full text not available from this repository. (Request a copy)

AIMS

We aimed to assess possible differences in neointimal quality after everolimus-eluting bioresorbable scaffold (BVS) implantation in comparison with cobalt-chromium everolimus-eluting scaffold (CoCr-EES) implantation by optical frequency domain imaging (OFDI).

METHODS AND RESULTS

This study is a post hoc analysis of the TROFI II trial assessing neointimal quality six months after the implantation of BVS (N=82) and CoCr-EES (N=87) in STEMI patients. Neointimal light property analysis by OFDI fully automatically computed light attenuation, backscatter and light intensity for superficial and deep neointima. High light attenuation/backscatter and high light intensity are reportedly associated with lipidic change and tissue maturation, respectively. Superficial and deep neointima in BVS presented lower light attenuation than CoCr-EES (superficial: 0.77±0.15 vs. 1.27±0.55 mm-1, p<0.001; deep: 0.88±0.20 vs. 1.17±0.27 mm-1, p<0.001). Superficial neointima in BVS showed comparable backscatter to that of CoCr-EES (4.81±0.52 vs. 4.94±0.61, p=0.141), while deep neointima in BVS showed lower backscatter than that of CoCr-EES (4.60±0.62 vs. 4.97±0.62, p<0.001). Light intensity of superficial neointima was comparable between both arms (139±13 vs. 144±30, p=0.236), whereas light intensity of deep neointima in BVS was lower than CoCr-EES (129±14 vs. 138±21, p<0.001).

CONCLUSIONS

The present OFDI comparison suggested that tissue maturation was comparable but lipidic change of neointima was less prominent after BVS than after CoCr-EES implantation.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

UniBE Contributor:

Räber, Lorenz, Windecker, Stephan

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1774-024X

Publisher:

Europa Digital & Publishing

Language:

English

Submitter:

Nadia Biscozzo

Date Deposited:

14 Mar 2019 11:12

Last Modified:

05 Dec 2022 15:26

Publisher DOI:

10.4244/EIJ-D-17-00884

PubMed ID:

29488886

URI:

https://boris.unibe.ch/id/eprint/125917

Actions (login required)

Edit item Edit item
Provide Feedback