Proposed achievable levels of dose and impact of dose-reduction systems for thrombectomy in acute ischemic stroke: an international, multicentric, retrospective study in 1096 patients.

Guenego, Adrien; Mosimann, Pascal John; Pereira, Vitor Mendes; Nicholson, Patrick; Zuber, Kevin; Lotterie, Jean Albert; Dobrocky, Tomas; Marcellus, David G; Olivot, Jean Marc; Piotin, Michel; Gralla, Jan; Fahed, Robert; Wintermark, Max; Heit, Jeremy J; Cognard, Christophe (2019). Proposed achievable levels of dose and impact of dose-reduction systems for thrombectomy in acute ischemic stroke: an international, multicentric, retrospective study in 1096 patients. European radiology, 29(7), pp. 3506-3515. Springer-Verlag 10.1007/s00330-019-06062-6

[img]
Preview
Text
Guenego2019_Article_ProposedAchievableLevelsOfDose.pdf - Published Version
Available under License Publisher holds Copyright.

Download (391kB) | Preview

BACKGROUND

International dose reference levels are lacking for mechanical thrombectomy in acute ischemic stroke patients with large vessel occlusions. We studied whether radiation dose-reduction systems (RDS) could effectively reduce exposure and propose achievable levels.

MATERIALS AND METHODS

We retrospectively included consecutive patients treated with thrombectomy on a biplane angiography system (BP) in five international, high-volume centers between January 2014 and May 2017. Institutional Review Board approvals were obtained. Technical, procedural, and clinical characteristics were assessed. Efficacy, safety, radiation dose, and contrast load were compared between angiography systems with and without RDS. Multivariate analyses were adjusted according to Bonferroni's correction. Proposed international achievable cutoff levels were set at the 75th percentile.

RESULTS

Out of the 1096 thrombectomized patients, 520 (47%) were treated on a BP equipped with RDS. After multivariate analysis, RDS significantly reduced dose-area product (DAP) (91 vs 140 Gy cm, relative effect 0.74 (CI 0.66; 0.83), 35% decrease, p < 0.001) and air kerma (0.46 vs 0.97 Gy, relative effect 0.63 (CI 0.56; 0.71), 53% decrease, p < 0.001) with 75th percentile levels of 148 Gy cm and 0.73 Gy, respectively. There was no difference in contrast load, rates of successful recanalization, complications, or clinical outcome.

CONCLUSION

Radiation dose-reduction systems can reduce DAP and air kerma by a third and a half, respectively, without affecting thrombectomy efficacy or safety. The respective thresholds of 148 Gy cm and 0.73 Gy represent achievable levels that may serve to optimize current and future radiation exposure in the setting of acute ischemic stroke treatment. As technology evolves, we expect these values to decrease.

KEY POINTS

• Internationally validated achievable levels may help caregivers and health authorities better assess and reduce radiation exposure of both ischemic stroke patients and treating staff during thrombectomy procedures. • Radiation dose-reduction systems can reduce DAP and air kerma by a third and a half, respectively, without affecting thrombectomy efficacy or safety in the setting of acute ischemic stroke due to large vessel occlusion.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic and Interventional Neuroradiology

UniBE Contributor:

Mosimann, Pascal John, Dobrocky, Tomas, Gralla, Jan

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0938-7994

Publisher:

Springer-Verlag

Language:

English

Submitter:

Martin Zbinden

Date Deposited:

31 May 2019 13:58

Last Modified:

24 Mar 2023 00:25

Publisher DOI:

10.1007/s00330-019-06062-6

PubMed ID:

30903333

Uncontrolled Keywords:

Patient safety Stroke Thrombectomy

BORIS DOI:

10.7892/boris.129406

URI:

https://boris.unibe.ch/id/eprint/129406

Actions (login required)

Edit item Edit item
Provide Feedback