Five-Year Outcomes in Patients With Diabetes Mellitus Treated With Biodegradable Polymer Sirolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents.

Iglesias, Juan F; Heg, Dik; Roffi, Marco; Tüller, David; Lanz, Jonas; Rigamonti, Fabio; Muller, Olivier; Moarof, Igal; Cook, Stéphane; Weilenmann, Daniel; Kaiser, Christoph; Cuculi, Florim; Valgimigli, Marco; Jüni, Peter; Windecker, Stephan; Pilgrim, Thomas (2019). Five-Year Outcomes in Patients With Diabetes Mellitus Treated With Biodegradable Polymer Sirolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents. Journal of the American Heart Association, 8(22), e013607. American Heart Association 10.1161/JAHA.119.013607

[img]
Preview
Text
Iglesias JAmHeartAssoc 2019.pdf - Published Version
Available under License Creative Commons: Attribution-Noncommercial-No Derivative Works (CC-BY-NC-ND).

Download (1MB) | Preview

Background The choice of optimal drug-eluting stent therapy for patients with diabetes mellitus (DM) undergoing percutaneous coronary intervention remains uncertain. We aimed to assess the long-term clinical outcomes after percutaneous coronary intervention with biodegradable polymer sirolimus-eluting stents (BP-SES) versus durable polymer everolimus-eluting stents (DP-EES) in patients with DM. Methods and Results In a prespecified subgroup analysis of the BIOSCIENCE (Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularization) trial (NCT01443104), patients randomly assigned to ultrathin-strut BP-SES or thin-strut DP-EES were stratified according to diabetic status. The primary end point was target lesion failure, a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularization, at 5 years. Among 2119 patients, 486 (22.9%) presented with DM. Compared with individuals without DM, patients with DM were older and had a greater baseline cardiac risk profile. In patients with DM, target lesion failure at 5 years occurred in 74 patients (cumulative incidence, 31.0%) treated with BP-SES and 57 patients (25.8%) treated with DP-EES (risk ratio, 1.23; 95% CI, 0.87-1.73 [P=0.24]). In individuals without DM, target lesion failure at 5 years occurred in 124 patients (16.8%) treated with BP-SES and 132 patients (16.8%) treated with DP-EES (risk ratio, 0.98; 95% CI, 0.77-1.26 [P=0.90; P for interaction=0.31]). Cumulative 5-year incidence rates of cardiac death, target vessel myocardial infarction, clinically indicated target lesion revascularization, and definite stent thrombosis were similar among patients with DM treated with BP-SES or DP-EES. There was no interaction between diabetic status and treatment effect of BP-SES versus DP-EES. Conclusions In a prespecified subgroup analysis of the BIOSCIENCE trial, we found no difference in clinical outcomes throughout 5 years between patients with DM treated with ultrathin-strut BP-SES or thin-strut DP-EES. Clinical Trial Registration URL: https://www.clinicaltrials.gov/. Unique identifier: NCT01443104.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology
04 Faculty of Medicine > Pre-clinic Human Medicine > Institute of Social and Preventive Medicine (ISPM)
04 Faculty of Medicine > Pre-clinic Human Medicine > Department of Clinical Research (DCR)

UniBE Contributor:

Heg, Dierik Hans, Lanz, Jonas, Valgimigli, Marco, Windecker, Stephan, Pilgrim, Thomas

Subjects:

600 Technology > 610 Medicine & health
300 Social sciences, sociology & anthropology > 360 Social problems & social services

ISSN:

2047-9980

Publisher:

American Heart Association

Language:

English

Submitter:

Andrea Flükiger-Flückiger

Date Deposited:

14 Nov 2019 15:41

Last Modified:

20 Feb 2024 14:16

Publisher DOI:

10.1161/JAHA.119.013607

PubMed ID:

31696762

Uncontrolled Keywords:

biodegradable polymer diabetes mellitus drug‐eluting stent long‐term outcomes ultrathin stent strut

BORIS DOI:

10.7892/boris.134889

URI:

https://boris.unibe.ch/id/eprint/134889

Actions (login required)

Edit item Edit item
Provide Feedback