Microstructural Integrity of Salvaged Penumbra after Mechanical Thrombectomy.

Berndt, M T; Maegerlein, C; Boeckh-Behrens, T; Wunderlich, S; Zimmer, C; Wirth, S; Mück, F G; Mönch, S; Friedrich, B; Kaesmacher, Johannes (2020). Microstructural Integrity of Salvaged Penumbra after Mechanical Thrombectomy. AJNR. American journal of neuroradiology, 41(1), pp. 79-85. American Society of Neuroradiology 10.3174/ajnr.A6364

[img] Text
Kasemacher_ajnr.A6364.full.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (1MB) | Request a copy

BACKGROUND AND PURPOSE

There are sparse data on the microstructural integrity of salvaged penumbral tissue after mechanical thrombectomy of large-vessel occlusions. The aim of the study was to analyze possible microstructural alteration in the penumbra and their association with clinical symptoms as well as angiographic reperfusion success in patients undergoing mechanical thrombectomy.

MATERIALS AND METHODS

All patients who underwent mechanical thrombectomy for large-vessel occlusions in the anterior circulation and who received an admission CT perfusion together with postinterventional DTIs were included (n = 65). Angiographic reperfusion success by means of modified Thrombolysis in Cerebral Infarction (mTICI) scale and clinical outcome were recorded. Microstructural integrity was assessed by DTI evaluating the mean diffusivity index within the salvaged gray matter of the former penumbra.

RESULTS

The mean diffusivity index was higher in completely recanalized patients (mTICI 3: -0.001 ± 0.034 versus mTICI <3: -0.030 ± 0.055, P = .03). There was a positive correlation between the mean diffusivity index and NIHSS score improvement (r = 0.49, P = .003) and the mean diffusivity index was associated with midterm functional outcome (r = -0.37, P = .04) after adjustment for confounders. In mediation analysis, the mean diffusivity index and infarction growth mediated the association between reperfusion success and clinical outcomes.

CONCLUSIONS

The macroscopic salvaged penumbra included areas of microstructural integrity changes, most likely related to the initial hypoperfusion. These abnormalities were found early after mechanical thrombectomy, were dependent on angiographic results, and correlated with the clinical outcome. When confirmed, these findings prompt the evaluation of therapies for protection of the penumbral tissue integrity.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic and Interventional Neuroradiology

UniBE Contributor:

Kaesmacher, Johannes

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1936-959X

Publisher:

American Society of Neuroradiology

Language:

English

Submitter:

Maria de Fatima Henriques Bernardo

Date Deposited:

29 Jan 2020 11:07

Last Modified:

05 Dec 2022 15:35

Publisher DOI:

10.3174/ajnr.A6364

PubMed ID:

31857324

BORIS DOI:

10.7892/boris.138077

URI:

https://boris.unibe.ch/id/eprint/138077

Actions (login required)

Edit item Edit item
Provide Feedback