Transcatheter Aortic Valve Replacement: Role of Multimodality Imaging in Common and Complex Clinical Scenarios.

Bax, Jeroen J; Delgado, Victoria; Hahn, Rebecca T; Leipsic, Jonathon; Min, James K; Grayburn, Paul; Sondergaard, Lars; Yoon, Sung-Han; Windecker, Stephan (2020). Transcatheter Aortic Valve Replacement: Role of Multimodality Imaging in Common and Complex Clinical Scenarios. JACC. Cardiovascular imaging, 13(1 Pt 1), pp. 124-139. Elsevier 10.1016/j.jcmg.2018.10.037

[img] Text
Transcatheter Aortic Valve Replacement Role of Multimodality Imaging.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (5MB) | Request a copy

Transcatheter aortic valve replacement (TAVR) is an established therapy for patients with symptomatic severe aortic stenosis. Technological advances and the learning curve have resulted in better procedural results in terms of hemodynamic valve performance and intermediate-term clinical outcomes. The integration of anatomical and functional information provided by multimodality imaging has improved size selection of TAVR prostheses, permitted better patient selection, and provided new insights in the performance of the TAVR prostheses at follow-up. Furthermore, the field of TAVR continues to develop and expand the technique to younger patients with lower risk on the one hand, and more complex clinical scenarios, on the other hand, such as degenerated aortic bioprostheses, bicuspid aortic valves, or pure native aortic regurgitation. The present review article summarizes how multimodality imaging can be integrated in TAVR in clinical (sometimes complex) scenarios that have not been included in the landmark randomized clinical trials.

Item Type:

Journal Article (Review Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

UniBE Contributor:

Windecker, Stephan

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1936-878X

Publisher:

Elsevier

Language:

English

Submitter:

Nadia Biscozzo

Date Deposited:

29 Jan 2020 09:28

Last Modified:

05 Dec 2022 15:35

Publisher DOI:

10.1016/j.jcmg.2018.10.037

PubMed ID:

31103575

Uncontrolled Keywords:

aortic regurgitation bicuspid aortic valve echocardiography multi-detector row computed tomography transcatheter aortic valve replacement

BORIS DOI:

10.7892/boris.139143

URI:

https://boris.unibe.ch/id/eprint/139143

Actions (login required)

Edit item Edit item
Provide Feedback