Invasive Assessment of the Human Arterial Palmar Arch and Forearm Collateral Function During Transradial Access.

Bigler, Marius Reto; Buffle, Eric; Siontis, George C. M.; Stoller, Michael; Grossenbacher, Raphael; Tschannen, Christine; Seiler, Christian (2019). Invasive Assessment of the Human Arterial Palmar Arch and Forearm Collateral Function During Transradial Access. Circulation. Cardiovascular interventions, 12(7), e007744. American Heart Association 10.1161/CIRCINTERVENTIONS.118.007744

[img] Text
CIRCINTERVENTIONS.118.007744.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (340kB) | Request a copy

BACKGROUND

The present study aimed to quantitatively measure the pressure-derived function of the palmar arch and forearm arterial collateral circulation during transradial access.

METHODS AND RESULTS

Palmar arch and forearm collateral function was determined using radial artery pressure signals in the nonobstructed vessel and during brief manual occlusions of the more proximal radial artery and of the radial plus ulnar arteries. Collateral flow index (CFI), the ratio of mean occlusive divided by mean nonocclusive arterial blood pressure, both subtracted by central venous pressure, was determined for CFI during radial artery occlusion (CFIrad) and CFI during radial plus ulnar artery occlusion. Before invasive CFI measurements, arterial palmar arch and forearm function was tested noninvasively by the modified Allen test (MAT). Two hundred fifty patients undergoing transradial access coronary angiography were included in the study. CFIrad was equal to 0.802±0.150 (95% CI, 0.783-0.820). CFI during radial plus ulnar artery occlusion was equal to 0.424±0.188 (95% CI, 0.400-0.447). There was an inverse linear relation between CFIrad and MAT in seconds (s): MAT=64-63×CFIrad ( r2=0.229; P<0.0001). Two hundred eleven patients had a normal and 39 patients an abnormal (>15 seconds) MAT. The group with normal MAT had a CFIrad of 0.830±0.111, and patients with abnormal MAT had a CFIrad of 0.648±0.224 ( P<0.0001).

CONCLUSIONS

Direct invasive hemodynamic assessment of the palmar arch and forearm arterial function reveals collateral supply to the briefly occluded in comparison to the patent radial artery of 0.802. During external occlusion of both radial and ulnar artery, CFI amounts to an unexpectedly high value of 0.424.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

UniBE Contributor:

Bigler, Marius Reto, Buffle, Eric Jacques, Grossenbacher, Raphael, Seiler, Christian

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1941-7632

Publisher:

American Heart Association

Language:

English

Submitter:

Andrea Stettler

Date Deposited:

02 Mar 2020 14:10

Last Modified:

05 Dec 2022 15:37

Publisher DOI:

10.1161/CIRCINTERVENTIONS.118.007744

PubMed ID:

31272228

Uncontrolled Keywords:

central venous pressure collateral circulation forearm radial artery ulnar artery

BORIS DOI:

10.7892/boris.141212

URI:

https://boris.unibe.ch/id/eprint/141212

Actions (login required)

Edit item Edit item
Provide Feedback