Low-profile Zenith Alpha™ Thoracic Stent Graft Modification Using Preloaded Wires for Urgent Repair of Thoracoabdominal and Pararenal Abdominal Aortic Aneurysms

Han, Sukgu M.; Tenorio, Emanuel R.; Mirza, Aleem K.; Zhang, Louis; Weiss, Salome; Oderich, Gustavo S. (2020). Low-profile Zenith Alpha™ Thoracic Stent Graft Modification Using Preloaded Wires for Urgent Repair of Thoracoabdominal and Pararenal Abdominal Aortic Aneurysms. Annals of vascular surgery, 67, pp. 14-25. Elsevier 10.1016/j.avsg.2020.02.022

[img]
Preview
Text
Low-profile Zenith Alpha™ Thoracic stent graft modification using pre-loaded wires for urgent repair of thoracoabdominal and pararenal abdominal aortic aneurysms.pdf - Accepted Version
Available under License Publisher holds Copyright.

Download (26MB) | Preview
[img] Text
1-s2.0-S0890509620302223-main.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (3MB) | Request a copy

Background: The aim of this study is to describe a modification technique using the low-profile Cook Zenith Alpha™ thoracic stent graft, and addition of a preloaded wire system, for urgent repair of pararenal (PRA) and thoracoabdominal (TAAA) aortic aneurysms.

Methods: We analyzed 20 consecutive patients who underwent urgent physician modified endograft repair (PMEG) of PRA and TAAA at 2 institutions. The low-profile Cook Zenith Alpha Thoracic stent graft was modified in accordance with each specific patient anatomic characteristics. End points were technical success, 30-day mortality, and major adverse events (MAEs).

Results: Technical success was achieved in all patients (100%). A total of 76 renal-mesenteric arteries were incorporated by fenestrations (70%) or directional branches (30%) with an average of 3.7 ± 0.6 vessels per patient. There were 6 different types of stent configuration. The most common design consisted of 4 fenestrations (9 patients, 45%). The average of modification time was 110 ± 27 minutes. Total procedure time (including the time for open component) was 242 ± 75 minutes. There was no death within the first 30 days or hospital stay. MAEs occurred in 10 patients (50%). The most common MAEs were acute kidney injury (by Risk, Injury, and Failure; and Loss; and End-stage kidney disease criteria) in 6 patients (30%), estimated blood loss >1 L, respiratory failure requiring reintubation in 2 patients (10%) each, and paraplegia and ischemic colitis in 1 patient (5%) each. One patient (5%) required temporary, new-onset dialysis.

Conclusions: PMEG using low-profile Zenith Alpha thoracic stent graft was safe with no early mortality and acceptable early morbidity.

Copyright © 2020 Elsevier Inc. All rights reserved.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Heart Surgery

UniBE Contributor:

Weiss, Salome

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1615-5947

Publisher:

Elsevier

Language:

English

Submitter:

Claudia Stalder

Date Deposited:

28 Apr 2020 16:27

Last Modified:

27 Feb 2024 14:28

Publisher DOI:

10.1016/j.avsg.2020.02.022

PubMed ID:

32205248

BORIS DOI:

10.7892/boris.143441

URI:

https://boris.unibe.ch/id/eprint/143441

Actions (login required)

Edit item Edit item
Provide Feedback