Three-dimensional facial capture using a custom-built photogrammetry setup: Design, performance, and cost.

Wellens, Hans L L; Hoskens, Hanne; Claes, Peter; Kuijpers-Jagtman, Anne Marie; Ortega-Castrillón, Alejandra (2020). Three-dimensional facial capture using a custom-built photogrammetry setup: Design, performance, and cost. American journal of orthodontics and dentofacial orthopedics, 158(2), pp. 286-299. Elsevier 10.1016/j.ajodo.2020.01.016

[img] Text
j.ajodo.2020.01.016 .pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (3MB) | Request a copy

INTRODUCTION

Although stereophotogrammetry is increasingly popular for 3-dimensional face scanning, commercial solutions remain quite expensive, limiting its accessibility. We propose a more affordable, custom-built photogrammetry setup (Stereo-Face 3D, SF3D) and evaluate its variability within and between systems.

METHODS

Twenty-nine subjects and a mannequin head were imaged 3 times using SF3D and a commercially available system. An anthropometric mask was mapped viscoelastically onto the reconstructed meshes using MeshMonk (https://github.com/TheWebMonks/meshmonk). Within systems, shape variability was determined by calculating the root-mean-square error (RMSE) of the Procrustes distance between each of the subject's 3 scans and the subject's ground truth (calculated by averaging the mappings after a nonscaled generalized Procrustes superimposition). Intersystem variability was determined by similarly comparing the ground truth mappings of both systems. Two-factor Procrustes analysis of variance was used to partition the intersystem shape variability to understand the source of the discrepancies between the facial shapes acquired by both systems.

RESULTS

The RMSEs of the within-system shape variability for 3dMDFace and SF3D were 0.52 ± 0.07 mm and 0.44 ± 0.16 mm, respectively. The corresponding values for the mannequin head were 0.42 ± 0.02 mm and 0.29 ± 0.03 mm, respectively. The between-systems RMSE was 1.6 ± 0.34 mm for the study group and 1.38 mm for the mannequin head. A 2-factor analysis indicated that variability attributable to the system was expressed mainly at the upper eyelids, nasal tip and alae, and chin areas.

CONCLUSIONS

The variability values of the custom-built setup presented here were competitive to a state-of-the-art commercial system at a more affordable level of investment.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Orthodontics

UniBE Contributor:

Kuijpers-Jagtman, Anne-Marie

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1097-6752

Publisher:

Elsevier

Language:

English

Submitter:

Renate Imhof-Etter

Date Deposited:

18 Aug 2020 10:36

Last Modified:

05 Dec 2022 15:40

Publisher DOI:

10.1016/j.ajodo.2020.01.016

PubMed ID:

32746977

BORIS DOI:

10.7892/boris.145945

URI:

https://boris.unibe.ch/id/eprint/145945

Actions (login required)

Edit item Edit item
Provide Feedback