Minimum perceivable size difference: how well can radiologists visually detect a change in lung nodule size from CT images?

Solomon, Justin; Ebner, Lukas; Christe, Andreas; Peters, Alan; Munz, Jaro; Löbelenz, Laura; Klaus, Jeremias; Richards, Taylor; Samei, Ehsan; Roos, Justus E (2021). Minimum perceivable size difference: how well can radiologists visually detect a change in lung nodule size from CT images? European radiology, 31(4), pp. 1947-1955. Springer-Verlag 10.1007/s00330-020-07326-2

[img] Text
Solomon2020_Article_MinimumPerceivableSizeDifferen.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (1MB) | Request a copy

OBJECTIVE

The purpose of this study was to determine how well radiologists could visually detect a change in lung nodule size on the basis of visual image perception alone.

SUBJECTS AND METHODS

Under IRB approval, 109 standard chest CT image series were anonymized and exported from PACS. Nine hundred forty virtual lung nodule pairs (six baseline diameters, six relative volume differences, two nodule types-solid and ground glass-and 14 repeats) were digitally inserted into the chest CT image series (same location, different sizes between the pair). These digitally altered CT image pairs were shown to nine radiologists who were tasked to visually determine which image contained the larger nodule using a two-alternative forced-choice perception experimental design. These data were statistically analyzed using a generalized linear mixed effects model to determine how accurately the radiologists were able to correctly identify the larger nodule.

RESULTS

Nominal baseline nodule diameter, relative volume difference, and nodule type were found to be statistically significant factors (p < 0.001) in influencing the radiologists' accuracy. For solid (ground-glass) nodules, the baseline diameter needed to be at least 6.3 mm (13.2 mm) to be able to visually detect a 25% change in volume with 95 ± 1.4% accuracy. Accuracy was lowest for the nodules with the smallest baseline diameters and smallest relative volume differences. Additionally, accuracy was lower for ground-glass nodules compared to solid nodules.

CONCLUSIONS

Factors that impacted visual size assessment were baseline nodule diameter, relative volume difference, and solid versus non-solid nodule type, with larger and more solid lesions offering a more precise assessment of change.

KEY POINTS

• For solid nodules, radiologists could visually detect a 25% change in volume with 95% accuracy for nodules having greater than 6.3-mm baseline diameter. • For ground-glass nodules, radiologists could visually detect a 25% change in volume with 95% accuracy for nodules having greater than 13.2-mm baseline diameter. • Accuracy in detecting a change in nodule size began to stabilize around 90-100% for nodules with larger baseline diameters (> 8 mm for solid nodules, > 12 mm for ground-glass nodules) and larger relative volume differences (>15% for solid nodules, > 25% for ground-glass nodules).

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic, Interventional and Paediatric Radiology

UniBE Contributor:

Ebner, Lukas, Christe, Andreas, Peters, Alan Arthur, Munz, Jaro Manuele, Löbelenz, Laura Isabel, Klaus, Jeremias Bendicht

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0938-7994

Publisher:

Springer-Verlag

Language:

English

Submitter:

Maria de Fatima Henriques Bernardo

Date Deposited:

26 Oct 2020 07:47

Last Modified:

05 Dec 2022 15:41

Publisher DOI:

10.1007/s00330-020-07326-2

PubMed ID:

32997175

Uncontrolled Keywords:

Lung neoplasms Multidetector computed tomography Radiologists Task performance and analysis, Visual perception