The potential of Gantry beamline large momentum acceptance for real time tumour tracking in pencil beam scanning proton therapy.

Fattori, Giovanni; Zhang, Ye; Meer, David; Weber, Damien Charles; Lomax, Antony John; Safai, Sairos (2020). The potential of Gantry beamline large momentum acceptance for real time tumour tracking in pencil beam scanning proton therapy. Scientific reports, 10(1), p. 15325. Springer Nature 10.1038/s41598-020-71821-1

[img]
Preview
Text
s41598-020-71821-1.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (2MB) | Preview

Tumour tracking is an advanced radiotherapy technique for precise treatment of tumours subject to organ motion. In this work, we addressed crucial aspects of dose delivery for its realisation in pencil beam scanning proton therapy, exploring the momentum acceptance and global achromaticity of a Gantry beamline to perform continuous energy regulation with a standard upstream degrader. This novel approach is validated on simulation data from three geometric phantoms of increasing complexity and one liver cancer patient using 4D dose calculations. Results from a standard high-to-low beamline ramping scheme were compared to alternative energy meandering schemes including combinations with rescanning. Target coverage and dose conformity were generally well recovered with tumour tracking even though for particularly small targets, large variations are reported for the different approaches. Meandering in energy while rescanning has a positive impact on target homogeneity and similarly, hot spots outside the targets are mitigated with a relatively fast convergence rate for most tracking scenarios, halving the volume of hot spots after as little as 3 rescans. This work investigates the yet unexplored potential of having a large momentum acceptance in medical beam line, and provides an alternative to take tumour tracking with particle therapy closer to clinical translation.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Haematology, Oncology, Infectious Diseases, Laboratory Medicine and Hospital Pharmacy (DOLS) > Clinic of Radiation Oncology

UniBE Contributor:

Weber, Damien Charles

Subjects:

600 Technology > 610 Medicine & health

ISSN:

2045-2322

Publisher:

Springer Nature

Language:

English

Submitter:

Ramona Wenholt

Date Deposited:

03 Nov 2020 17:29

Last Modified:

05 Dec 2022 15:41

Publisher DOI:

10.1038/s41598-020-71821-1

PubMed ID:

32948790

BORIS DOI:

10.7892/boris.147332

URI:

https://boris.unibe.ch/id/eprint/147332

Actions (login required)

Edit item Edit item
Provide Feedback