Mantokoudis, Georgios; Wyss, Thomas; Zamaro, Ewa; Korda, Athanasia; Wagner, Franca; Sauter, Thomas C; Kerkeni, Hassen; Kalla, Roger; Morrison, Miranda Claire; Caversaccio, Marco Domenico (2021). Stroke Prediction Based on the Spontaneous Nystagmus Suppression Test in Dizzy Patients: A Diagnostic Accuracy Study. Neurology, 97(1), e42-e51. American Academy of Neurology 10.1212/WNL.0000000000012176

[img]
Preview
Text
e42.full.pdf - Published Version
Available under License Creative Commons: Attribution-Noncommercial-No Derivative Works (CC-BY-NC-ND).

Download (587kB) | Preview

ObjectiveFailure of fixation suppression of spontaneous nystagmus is sometimes seen in patients with vestibular strokes involving the cerebellum or brainstem, however, the accuracy of this test for the discrimination between peripheral and central causes in patients with an acute vestibular syndrome (AVS) is unknown.MethodsPatients with AVS were screened and recruited (convenience sample) as part of a prospective cross-sectional study in the Emergency Department between 2015-2020. All patients received neuroimaging which served as a reference standard. We recorded fixation suppression with video-oculography (VOG) for straight, right and left gaze. The ocular fixation index (OFI) and the spontaneous nystagmus slow velocity reduction was calculated.ResultsWe screened 1646 dizzy patients in the emergency department and tested for spontaneous nystagmus in 148 included AVS patients. We analyzed 56 patients with a diagnosed acute unilateral vestibulopathy (vestibular neuritis) and 28 patients with a confirmed stroke. There was a complete nystagmus fixation suppression in 49.5% of AVS patients, in 40% of patients with vestibular neuritis and in 62.5% of vestibular strokes. OFI scores had no predictive value for detecting strokes, however, a nystagmus reduction of less than 2deg/s showed a high accuracy of 76.9% (CI 0.59-0.89) with a sensitivity of 62.2% and specificity of 84.8% in detecting strokes..ConclusionsThe presence of fixation suppression does not rule out a central lesion. The magnitude of suppression was lower compared to patients with vestibular neuritis. The nystagmus suppression test still predicts accurately vestibular strokes provided that eye movements are recorded with VOG.Classification of EvidenceThis study provides Class II evidence that in patients with an acute vestibular syndrome, decreased fixation suppression recorded with VOG occurred more often in stroke (76.9%) than in vestibular neuritis (37.8%).

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Intensive Care, Emergency Medicine and Anaesthesiology (DINA) > University Emergency Center
04 Faculty of Medicine > Department of Head Organs and Neurology (DKNS) > Clinic of Neurology
04 Faculty of Medicine > Department of Head Organs and Neurology (DKNS) > Clinic of Ear, Nose and Throat Disorders (ENT)
04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic and Interventional Neuroradiology

UniBE Contributor:

Mantokoudis, Georgios, Wyss, Thomas Werner, Zamaro, Ewa, Korda, Athanasia, Wagner, Franca, Sauter, Thomas Christian, Kerkeni, Hassen, Kalla, Roger, Morrison, Miranda Claire, Caversaccio, Marco

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1526-632X

Publisher:

American Academy of Neurology

Language:

English

Submitter:

Martin Zbinden

Date Deposited:

06 Jul 2021 15:17

Last Modified:

02 Mar 2023 23:35

Publisher DOI:

10.1212/WNL.0000000000012176

PubMed ID:

33986142

BORIS DOI:

10.48350/157292

URI:

https://boris.unibe.ch/id/eprint/157292

Actions (login required)

Edit item Edit item
Provide Feedback