Precision of orthodontic cephalometric measurements on ultra low dose-low dose CBCT reconstructed cephalograms.

van Bunningen, R H; Dijkstra, P U; Dieters, A; van der Meer, W J; Kuijpers-Jagtman, A. M.; Ren, Y (2022). Precision of orthodontic cephalometric measurements on ultra low dose-low dose CBCT reconstructed cephalograms. Clinical oral investigations, 26(2), pp. 1543-1550. Springer-Verlag 10.1007/s00784-021-04127-9

[img]
Preview
Text
Bunningen2021_Article_PrecisionOfOrthodonticCephalom.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (711kB) | Preview

OBJECTIVES

To analyze differences in variation of orthodontic diagnostic measurements on lateral cephalograms reconstructed from ultra low dose-low dose (ULD-LD) cone beam computed tomography (CBCT) scans (RLC) as compared to variation of measurements on standard lateral cephalograms (SLC), and to determine if it is justifiable to replace a traditional orthodontic image set for an ULD-LD CBCT with a reconstructed lateral cephalogram.

MATERIAL AND METHODS

ULD-LD CBCT images and SLCs were made of forty-three dry human skulls. From the ULD-LD CBCT dataset, a lateral cephalogram was reconstructed (RLC). Cephalometric landmarks (13 skeletal and 7 dental) were identified on both SLC and RLC twice in two sessions by two calibrated observers. Thirteen cephalometric variables were calculated. Variations of measurements, expressed as standard deviations of the 4 measurements on SLC and RLC, were analyzed using a paired sample t-test. Differences in the number of observations deviating ≥ 2.0 mm or degrees from the grand mean between SLC and RLC were analyzed using a McNemar test.

RESULTS

Mean SDs for 7 out of 13 variables were significantly smaller for SLCs than those for RLCs, but differences were small. For 9 out of 13 variables, there was no significant difference between SLC and RLC for the number of measurements outside the range of 2 mm or degrees.

CONCLUSIONS

Based on the lower radiation dose and the small differences in variation in cephalometric measurements on reconstructed LC compared to standard dose LC, ULD-LD CBCT with reconstructed LC should be considered for orthodontic diagnostic purposes.

CLINICAL RELEVANCE

ULD-LD CBCT with reconstructed LC should be considered for orthodontic purposes.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Orthodontics

UniBE Contributor:

Kuijpers-Jagtman, Anne-Marie

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1432-6981

Publisher:

Springer-Verlag

Language:

English

Submitter:

Renate Imhof-Etter

Date Deposited:

11 Oct 2021 14:15

Last Modified:

05 Dec 2022 15:53

Publisher DOI:

10.1007/s00784-021-04127-9

PubMed ID:

34453209

Uncontrolled Keywords:

Accuracy Cephalometry Cone beam computed tomography Diagnosis Orthodontics Reliability Variation

BORIS DOI:

10.48350/159595

URI:

https://boris.unibe.ch/id/eprint/159595

Actions (login required)

Edit item Edit item
Provide Feedback