Wolf, Thomas Gerhard; Dekert, Natalie; Campus, Guglielmo; Ernst, Claus-Peter (2022). White‐opaque flowable composite liner as a depth marker in composite restorations prevents tooth substance loss in filling removal: a randomized double‐blinded in vitro study. Clinical oral investigations, 26(3), pp. 2711-2717. Springer-Verlag 10.1007/s00784-021-04244-5
|
Text
Wolf2021_Article_White-opaqueFlowableCompositeL.pdf - Published Version Available under License Creative Commons: Attribution (CC-BY). Download (1MB) | Preview |
Objectives Removal of esthetic restorations leads to loss of tooth structure and the extent of the loss is difficult to estimate due to exact-shade matching. This randomized double-blinded in vitro study aimed examining the influence of a white- opaque flowable composite depth marker as an optical removal aid for tooth substance preservation and shortened restoration removal time.
Materialsandmethods ClassIIcavities(n=100)inextractedhealthymandibularmolars(n=50,tworuns)wereprepared, filled, and the restoration removed. Tooth weight and volume (before and after) and removal time were measured and rem- nants visually documented. An optimal tooth shade-matched flowable composite liner was used as control.
Results Tooth structure loss was significantly lower using a white-opaque liner. Mean values for volume/weight loss were 0.037 ± 0.030 g and 0.016 ± 0.005 cm3 (p < 0.01) for white-opaque liner; 0.067 ± 0.000 g and 0.028 ± 0.003 cm3 (p < 0.01) for tooth-colored composite. Removal time and number of pulp chamber perforations showed no significant differences (p = 0.80).
Conclusions Within the limitations of this randomized double-blinded in vitro study, the use of a white-opaque flowable liner as a depth marker may provide the practitioner a visual aid in the replacement of a composite restoration and may protect against tooth structure loss.
Clinical relevance When restoration replacement is indicated, removal of esthetic restorations often causes tooth structure loss due to difficult optical color matching. Using a white-opaque flowable liner as a depth marker clinically aids in restora- tion removal and protects against tooth structure loss.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > School of Dental Medicine > Department of Preventive, Restorative and Pediatric Dentistry |
UniBE Contributor: |
Wolf, Thomas Gerhard, Campus, Guglielmo Giuseppe |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
1432-6981 |
Publisher: |
Springer-Verlag |
Language: |
English |
Submitter: |
Thomas Gerhard Wolf |
Date Deposited: |
03 Jan 2022 12:13 |
Last Modified: |
05 Dec 2022 15:55 |
Publisher DOI: |
10.1007/s00784-021-04244-5 |
PubMed ID: |
34714398 |
Uncontrolled Keywords: |
Composite · Depth marking · Restoration replacement · Tooth substance loss · Time requirement · White- opaque liner |
BORIS DOI: |
10.48350/162083 |
URI: |
https://boris.unibe.ch/id/eprint/162083 |