Trueness of Intraoral Scanners in Implant-Supported Rehabilitations: An In Vitro Analysis on the Effect of Operators' Experience and Implant Number.

Pesce, Paolo; Bagnasco, Francesco; Pancini, Nicolò; Colombo, Marco; Canullo, Luigi; Pera, Francesco; Bressan, Eriberto; Annunziata, Marco; Menini, Maria (2021). Trueness of Intraoral Scanners in Implant-Supported Rehabilitations: An In Vitro Analysis on the Effect of Operators' Experience and Implant Number. Journal of clinical medicine, 10(24) MDPI 10.3390/jcm10245917

[img]
Preview
Text
jcm-10-05917-v3.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (528kB) | Preview

(1) Background: Intraoral scanners (IOS) are widely used in prosthodontics. However, a good trueness is mandatory to achieve optimal clinical results. The aim of the present in vitro study was to compare two IOS considering the operator's experience and different implant clinical scenarios. (2) Methods: Two IOS (IT-Itero, Align Technology; and OP-Opera MC, Opera System, Monaco) were compared simulating three different clinical scenarios: single implant, two implants, and full-arch rehabilitation. Ten scans were taken for each configuration by two different operators (one expert, one inexperienced); influence of operator experience and the type of scanner used was investigated. (3) Results: Trueness of the scans differed between the experienced and non-experienced operator and this difference was statistically significant in all the three scenarios (p = 0.000-0.001, 0.037). A significant difference was present between the scanners (p = 0.000), in the two-implant and full-arch scenarios (p = 0.00). (4) Conclusions: Experience of the operator significantly affect trueness of IT and OP scanners. A statistically significant difference was present among IOS in the two-implant and full-arch scenarios.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Periodontology
04 Faculty of Medicine > School of Dental Medicine > Periodontics Research

UniBE Contributor:

Canullo, Luigi

Subjects:

600 Technology > 610 Medicine & health

ISSN:

2077-0383

Publisher:

MDPI

Language:

English

Submitter:

Doris Burri

Date Deposited:

26 Jan 2022 14:22

Last Modified:

05 Dec 2022 16:02

Publisher DOI:

10.3390/jcm10245917

PubMed ID:

34945211

Uncontrolled Keywords:

dental implants digital impression intraoral scanner

BORIS DOI:

10.48350/164130

URI:

https://boris.unibe.ch/id/eprint/164130

Actions (login required)

Edit item Edit item
Provide Feedback