Vibrating Membrane Devices Deliver Aerosols More Efficient than Standard Devices: A Study in a Neonatal Upper Airway Model

Tiemersma, Sybrich; Minocchieri, Stefan; van Lingen, Richard A.; Nelle, Mathias; Devadason, Sunalene G. (2012). Vibrating Membrane Devices Deliver Aerosols More Efficient than Standard Devices: A Study in a Neonatal Upper Airway Model. Journal of aerosol medicine and pulmonary drug delivery, 26(5), pp. 280-286. New York, N.Y.: Mary Ann Liebert 10.1089/jamp.2012.0993

Full text not available from this repository.

Abstract Background: Aerosol therapy in preterm infants is challenging, as a very small proportion of the drug deposits in the lungs. Aim: Our aim was to compare efficiency of standard devices with newer, more efficient aerosol delivery devices. Methods: Using salbutamol as a drug marker, we studied two prototypes of the investigational eFlow(®) nebulizer for babies (PARI Pharma GmbH), a jet nebulizer (Intersurgical(®) Cirrus(®)), and a pressurized metered dose inhaler (pMDI; GSK) with a detergent-coated holding chamber (AeroChamber(®) MV) in the premature infant nose throat-model (PrINT-model) of a 32-week preterm infant (1,750 g). A filter or an impactor was placed below the infant model's "trachea" to capture the drug dose or particle size, respectively, that would have been deposited in the lung. Results: Lung dose (percentage of nominal dose) was 1.5%, 6.8%, and 18.0-20.6% for the jet nebulizer, pMDI-holding chamber, and investigational eFlow nebulizers, respectively (p<0.001). Jet nebulizer residue was 69.4% and 10.7-13.9% for the investigational eFlow nebulizers (p<0.001). Adding an elbow extension between the eFlow and the model significantly lowered lung dose (p<0.001). A breathing pattern with lower tidal volume decreased deposition in the PrINT-model and device residue (p<0.05), but did not decrease lung dose. Conclusions: In a model for infant aerosol inhalation, we confirmed low lung dose using jet nebulizers and pMDI-holding chambers, whereas newer, more specialized vibrating membrane devices, designed specifically for use in preterm infants, deliver up to 20 times more drug to the infant's lung.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Gynaecology, Paediatrics and Endocrinology (DFKE) > Clinic of Paediatric Medicine
04 Faculty of Medicine > Department of Gynaecology, Paediatrics and Endocrinology (DFKE) > Clinic of Paediatric Medicine > Neonatology

UniBE Contributor:

Minocchieri, Stefan, Nelle, Mathias

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1941-2711

Publisher:

Mary Ann Liebert

Language:

English

Submitter:

Anette van Dorland

Date Deposited:

04 Oct 2013 14:41

Last Modified:

05 Dec 2022 14:12

Publisher DOI:

10.1089/jamp.2012.0993

PubMed ID:

23273244

URI:

https://boris.unibe.ch/id/eprint/16554 (FactScience: 224209)

Actions (login required)

Edit item Edit item
Provide Feedback