Three-dimensional perception of cinematic rendering versus conventional volume rendering using CT and CBCT data of the facial skeleton.

Steffen, Tobias; Winklhofer, Sebastian; Starz, Felicitas; Wiedemeier, Daniel; Ahmadli, Uzeyir; Stadlinger, Bernd (2022). Three-dimensional perception of cinematic rendering versus conventional volume rendering using CT and CBCT data of the facial skeleton. Annals of anatomy - Anatomischer Anzeiger, 241, p. 151905. Elsevier 10.1016/j.aanat.2022.151905

[img]
Preview
Text
1-s2.0-S0940960222000206-main.pdf - Published Version
Available under License Creative Commons: Attribution-Noncommercial-No Derivative Works (CC-BY-NC-ND).

Download (6MB) | Preview

The aim of this exploratory study is to analyse whether three-dimensional cinematic rendering image reconstructions offer advantages over conventional volume rendering in the visualisation of cone beam computed tomography (CBCT) and computed tomography (CT) images of the facial skeleton. This is of interest, as some information gets lost during the rendering process. This especially applies to structures in the background of the image and some surface information which can be lost. The commonly applied two-dimensional representation of CBCT or CT images in three different axes requires experience for interpretation. Cinematic rendering is a new three-dimensional post processing reconstruction technique, creating photo realistic visualisations, thus possibly enabling an easier interpretation of the images. In this study, ten investigators assessed ten separate patient cases of the orofacial skeleton. For each case, a conventional volume rendering image reconstruction and a cinematic rendering reconstruction of the same area was created. A specially designed questionnaire assessed both objective and subjective criteria of image perception. Objective criteria were assessed by predefined questions on the visual perception of anatomical image characteristics, showing the two reconstruction types of each case randomly to the investigators in two sessions. Subjective criteria were assessed via a visual analogue scale, showing both reconstructions simultaneously in a third session. The results show that cinematic rendering offers advantages especially in the evaluation of depth perception and three-dimensionality. Volume rendering shows advantages in surface sharpness. Cinematic Rendering was subjectively rated higher for almost all reconstructions. The cinematic rendering process however may cause loss of information and blurring of surfaces compared to volume rendering. With respect to the subjective impression, cinematic rendering scored better than volume rendering. The visualisation is perceived as being very close to reality.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic and Interventional Neuroradiology

UniBE Contributor:

Ahmadli, Uzeyir

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0940-9602

Publisher:

Elsevier

Language:

English

Submitter:

Pubmed Import

Date Deposited:

21 Feb 2022 17:05

Last Modified:

05 Dec 2022 16:09

Publisher DOI:

10.1016/j.aanat.2022.151905

PubMed ID:

35150863

Uncontrolled Keywords:

CBCT CT Cinematic rendering Facial skeleton Imaging Three-dimensional

BORIS DOI:

10.48350/165823

URI:

https://boris.unibe.ch/id/eprint/165823

Actions (login required)

Edit item Edit item
Provide Feedback