Tanaka, Aruki; Sekine, Tetsuro; Ter Voert, Edwin E G W; Zeimpekis, Konstantinos G; Delso, Gaspar; de Galiza Barbosa, Felipe; Warnock, Geoffrey; Kumita, Shin-Ichiro; Veit Haibach, Patrick; Huellner, Martin (2022). Reproducibility of Standardized Uptake Values Including Volume Metrics Between TOF-PET-MR and TOF-PET-CT. Frontiers in medicine, 9, p. 796085. Frontiers 10.3389/fmed.2022.796085
|
Text
fmed-09-796085.pdf - Published Version Available under License Creative Commons: Attribution (CC-BY). Download (1MB) | Preview |
Purpose
To investigate the reproducibility of tracer uptake measurements, including volume metrics, such as metabolic tumor volume (MTV) and tumor lesion glycolysis (TLG) obtained by TOF-PET-CT and TOF-PET-MR.
Materials and Methods
Eighty consecutive patients with different oncologic diagnoses underwent TOF-PET-CT (Discovery 690; GE Healthcare) and TOF-PET-MR (SIGNA PET-MR; GE Healthcare) on the same day with single dose-18F-FDG injection. The scan order, PET-CT following or followed by PET-MR, was randomly assigned. A spherical volume of interest (VOI) of 30 mm was placed on the liver in accordance with the PERCIST criteria. For liver, the maximum and mean standard uptake value for body weight (SUV) and lean body mass (SUL) were obtained. For tumor delineation, VOI with a threshold of 40 and 50% of SUVmax was used (VOI40 and VOI50). The SUVmax, SUVmean, SUVpeak, MTV and TLG were calculated. The measurements were compared between the two scanners.
Results
In total, 80 tumor lesions from 35 patients were evaluated. There was no statistical difference observed in liver regions, whereas in tumor lesions, SUVmax, SUV mean, and SUVpeak of PET-MR were significantly underestimated (p < 0.001) in both VOI40 and VOI50. Among volume metrics, there was no statistical difference observed except TLG on VOI50 (p = 0.03). Correlation between PET-CT and PET-MR of each metrics were calculated. There was a moderate correlation of the liver SUV and SUL metrics (r = 0.63-0.78). In tumor lesions, SUVmax and SUVmean had a stronger correlation with underestimation in PET-MR on VOI 40 (SUVmax and SUVmean; r = 0.92 and 0.91 with slope = 0.71 and 0.72, respectively). In the evaluation of MTV and TLG, the stronger correlations were observed both on VOI40 (MTV and TLG; r = 0.75 and 0.92) and VOI50 (MTV and TLG; r = 0.88 and 0.95) between PET-CT and PET-MR.
Conclusion
PET metrics on TOF-PET-MR showed a good correlation with that of TOF-PET-CT. SUVmax and SUVpeak of tumor lesions were underestimated by 16% on PET-MRI. MTV with % threshold can be regarded as identical volumetric markers for both TOF-PET-CT and TOF-PET-MR.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Clinic of Nuclear Medicine |
UniBE Contributor: |
Zeimpekis, Konstantinos |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
2296-858X |
Publisher: |
Frontiers |
Language: |
English |
Submitter: |
Pubmed Import |
Date Deposited: |
23 Mar 2022 09:49 |
Last Modified: |
05 Dec 2022 16:16 |
Publisher DOI: |
10.3389/fmed.2022.796085 |
PubMed ID: |
35308500 |
Uncontrolled Keywords: |
FDG-F production 18 PET/CT PET/MR SUV TOF (time-of-flight) metabolic tumor volume reproducibility |
BORIS DOI: |
10.48350/167855 |
URI: |
https://boris.unibe.ch/id/eprint/167855 |