Wolf, Thomas; Castañeda-López, Fernando; Gleißner, Lisa; Schulze, Ralf; Kuchen, Robert; Briseño-Marroquín, Benjamín (2022). Detectability of simulated apical lesions on mandibular premolars and molars between radiographic intraoral and cone-beam computed tomography images: an ex vivo study. Scientific Reports, 12(1), p. 14032. Nature Publishing Group 10.1038/s41598-022-18289-3
|
Text
s41598-022-18289-3.pdf - Published Version Available under License Creative Commons: Attribution (CC-BY). Download (2MB) | Preview |
Adequate endodontic diagnostic is essential when making a therapy decision. Radiographic imagining acquisition methods (IAMs) are fundamental apical lesions of endodontic (ALE) origin diagnose tool. Thus, the aim of this research was to compare the simulated apical lesions (SALs) diagnose potential of digital intraoral radiography (DIR) and cone-beam computed tomography (CBCT), if there is a relationship between the IAMs, SALs-depth and their correct diagnose likelihood in human mandibular specimens' datasets. 1024 SALs were prepared in cancellous and cortical bone with different penetration depths. The SALs-stages were radiographed with CBCT and DIR. The IAMs were randomly evaluated by 16 observers in two trials. Possible SAL findings were analyzed according to a five-point scale. The null hypothesis established that SALs detection accuracy does not differ between CBCT and DIR. Significantly differences (first 0.935 and second trial 0.960) were found for the CBCT area under the curve when compared with the DIR (first 0.859 and second trial 0.862) findings. SALs of smaller size were earlier detected by CBCT. In SALs without cortical involvement the probability of detection increased from 90 to 100%. The SALs-depth had the highest detectability influence on cancellous bone lesions and CBCT SALs detectability was 84.9% higher than with DIR images. The CBCT diagnose reproducibility was higher than the one of DIR (Kappa CBCT 75.7-81.4%; DIR 53.4-57.1%). Our results showed that CBCT has a higher SALs IAM diagnosing accuracy and that SALs detection accuracy incremented as the SALs-size increased.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > School of Dental Medicine > Department of Preventive, Restorative and Pediatric Dentistry 04 Faculty of Medicine > School of Dental Medicine > Department of Oral Surgery and Stomatology 04 Faculty of Medicine > School of Dental Medicine |
UniBE Contributor: |
Wolf, Thomas Gerhard, Schulze, Ralf Kurt Willy, Briseño Marroquin, Benjamin |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
2045-2322 |
Publisher: |
Nature Publishing Group |
Language: |
English |
Submitter: |
Pubmed Import |
Date Deposited: |
22 Aug 2022 10:18 |
Last Modified: |
05 Dec 2022 16:22 |
Publisher DOI: |
10.1038/s41598-022-18289-3 |
PubMed ID: |
35982122 |
BORIS DOI: |
10.48350/172225 |
URI: |
https://boris.unibe.ch/id/eprint/172225 |