The Hemodynamic Performance of the Perceval Sutureless Aortic Valve in a Propensity-Matched Comparison to the Carpentier-Edwards Perimount and Perimount Magna Ease Valves for Aortic Valve Replacement.

Kueri, Sami; Berger, Tim; Puiu, Paul-Cătălin; Alhamami, Yasir; Diab, Nawras; Czerny, Martin; Hochholzer, Willibald; Siepe, Matthias (2023). The Hemodynamic Performance of the Perceval Sutureless Aortic Valve in a Propensity-Matched Comparison to the Carpentier-Edwards Perimount and Perimount Magna Ease Valves for Aortic Valve Replacement. The Thoracic and cardiovascular surgeon, 71(7), pp. 542-549. Thieme 10.1055/s-0042-1755207

Full text not available from this repository.

OBJECTIVES

The Perceval valve was shown to facilitate minimal-invasive operations and shorten operative times. We aimed to compare the early results of the Perceval valve to those of well-established valves, namely the Carpentier-Edwards Perimount and Perimount Magna Ease valve protheses, in terms of their clinical and hemodynamic performances.

METHODS

This is a single-center, retrospective, observational cohort study. For every patient operated with a Perceval valve, the last patient before and the next following patient receiving a Perimount valve was included in a control group leading to a 2:1 ratio (Perimount:Perceval). A propensity score matching was used and a subgroup analysis was performed to compare early and late Perceval patients as the sizing technique was changed over time.

RESULTS

From November 2013 to November 2017, 423 patients were identified. These included 141 consecutive patients receiving a Perceval valve through a full- or a hemi-sternotomy. In addition, 282 patients receiving a Perimount or a Magna Ease valve were enrolled. After propensity score matching, 127 matched patients were compared. Operating times were shorter and postoperative transvalvular pressure gradients were lower in the Perceval group (15 vs. 17 mmHg, p = 0.002). There was no difference in mortality and stroke rates. The incidence of new pacemaker implantations was higher in the Perceval group (7.1 vs. 18.9%, p = 0.005), mainly due to a very high incidence in the early phase of our Perceval experience prior to a change in the Perceval implantation technique. Subgroup analysis showed significantly better results in the late Perceval group.

CONCLUSION

Surgical outcome was good in both groups. The Perceval valve exhibited lower postoperative gradients, and the need for pacemaker implantation was higher and can be reduced by avoiding oversizing.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Heart Surgery

UniBE Contributor:

Siepe, Matthias

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1439-1902

Publisher:

Thieme

Language:

English

Submitter:

Pubmed Import

Date Deposited:

24 Aug 2022 10:39

Last Modified:

27 Feb 2024 14:27

Publisher DOI:

10.1055/s-0042-1755207

PubMed ID:

35987191

URI:

https://boris.unibe.ch/id/eprint/172283