Coxa valga and antetorta increases differences among different femoral version measurements : potential implications for derotational femoral osteotomy planning.

Schmaranzer, Florian; Meier, Malin K; Lerch, Till D; Hecker, Andreas; Steppacher, Simon D; Novais, Eduardo N; Kiapour, Ata M (2022). Coxa valga and antetorta increases differences among different femoral version measurements : potential implications for derotational femoral osteotomy planning. Bone & joint open, 3(10), pp. 759-766. The British Editorial Society of Bone & Joint Surgery 10.1302/2633-1462.310.BJO-2022-0102.R1

[img]
Preview
Text
2633-1462.310.bjo-2022-0102.r1.pdf - Published Version
Available under License Creative Commons: Attribution-Noncommercial-No Derivative Works (CC-BY-NC-ND).

Download (1MB) | Preview

AIMS

To evaluate how abnormal proximal femoral anatomy affects different femoral version measurements in young patients with hip pain.

METHODS

First, femoral version was measured in 50 hips of symptomatic consecutively selected patients with hip pain (mean age 20 years (SD 6), 60% (n = 25) females) on preoperative CT scans using different measurement methods: Lee et al, Reikerås et al, Tomczak et al, and Murphy et al. Neck-shaft angle (NSA) and α angle were measured on coronal and radial CT images. Second, CT scans from three patients with femoral retroversion, normal femoral version, and anteversion were used to create 3D femur models, which were manipulated to generate models with different NSAs and different cam lesions, resulting in eight models per patient. Femoral version measurements were repeated on manipulated femora.

RESULTS

Comparing the different measurement methods for femoral version resulted in a maximum mean difference of 18° (95% CI 16 to 20) between the most proximal (Lee et al) and most distal (Murphy et al) methods. Higher differences in proximal and distal femoral version measurement techniques were seen in femora with greater femoral version (r > 0.46; p < 0.001) and greater NSA (r > 0.37; p = 0.008) between all measurement methods. In the parametric 3D manipulation analysis, differences in femoral version increased 11° and 9° in patients with high and normal femoral version, respectively, with increasing NSA (110° to 150°).

CONCLUSION

Measurement of femoral version angles differ depending on the method used to almost 20°, which is in the range of the aimed surgical correction in derotational femoral osteotomy and thus can be considered clinically relevant. Differences between proximal and distal measurement methods further increase by increasing femoral version and NSA. Measurement methods that take the entire proximal femur into account by using distal landmarks may produce more sensitive measurements of these differences.Cite this article: Bone Jt Open 2022;3(10):759-766.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Orthopaedic, Plastic and Hand Surgery (DOPH) > Clinic of Orthopaedic Surgery
04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic, Interventional and Paediatric Radiology

UniBE Contributor:

Schmaranzer, Florian, Meier, Malin Kristin, Lerch, Till, Hecker, Andreas, Steppacher, Simon Damian

Subjects:

600 Technology > 610 Medicine & health

ISSN:

2633-1462

Publisher:

The British Editorial Society of Bone & Joint Surgery

Language:

English

Submitter:

Pubmed Import

Date Deposited:

06 Oct 2022 12:38

Last Modified:

05 Dec 2022 16:26

Publisher DOI:

10.1302/2633-1462.310.BJO-2022-0102.R1

PubMed ID:

36196582

Uncontrolled Keywords:

CT scans Coxa valga Femoral acetabular impingement Femoral derotational osteotomy Femoral version Hip joint preserving surgery femora femoral osteotomies femoral retroversion hip pain hips neck shaft angles proximal femur