Treatment planning comparison in the PROTECT-trial randomising proton versus photon beam therapy in oesophageal cancer: Results from eight European centres.

Hoffmann, Lone; Mortensen, Hanna; Shamshad, Muhammad; Berbee, Maaike; Bizzocchi, Nicola; Bütof, Rebecca; Canters, Richard; Defraene, Gilles; Ehmsen, Mai Lykkegaard; Fiorini, Francesca; Haustermans, Karin; Hulley, Ryan; Korevaar, Erik W; Clarke, Matthew; Makocki, Sebastian; Muijs, Christina T; Murray, Luke; Nicholas, Owen; Nordsmark, Marianne; Radhakrishna, Ganesh; ... (2022). Treatment planning comparison in the PROTECT-trial randomising proton versus photon beam therapy in oesophageal cancer: Results from eight European centres. Radiotherapy and oncology, 172, pp. 32-41. Elsevier 10.1016/j.radonc.2022.04.029

[img]
Preview
Text
1-s2.0-S0167814022002353-main.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (3MB) | Preview

PURPOSE

To compare dose distributions and robustness in treatment plans from eight European centres in preparation for the European randomized phase-III PROTECT-trial investigating the effect of proton therapy (PT) versus photon therapy (XT) for oesophageal cancer.

MATERIALS AND METHODS

All centres optimized one PT and one XT nominal plan using delineated 4DCT scans for four patients receiving 50.4 Gy (RBE) in 28 fractions. Target volume receiving 95% of prescribed dose (V95%iCTVtotal) should be >99%. Robustness towards setup, range, and respiration was evaluated. The plans were recalculated on a surveillance 4DCT (sCT) acquired at fraction ten and robustness evaluation was performed to evaluate the effect of respiration and inter-fractional anatomical changes.

RESULTS

All PT and XT plans complied with V95%iCTVtotal >99% for the nominal plan and V95%iCTVtotal >97% for all respiratory and robustness scenarios. Lung and heart dose varied considerably between centres for both modalities. The difference in mean lung dose and mean heart dose between each pair of XT and PT plans was in median [range] 4.8 Gy [1.1;7.6] and 8.4 Gy [1.9;24.5], respectively. Patients B and C showed large inter-fractional anatomical changes on sCT. For patient B, the minimum V95%iCTVtotal in the worst-case robustness scenario was 45% and 94% for XT and PT, respectively. For patient C, the minimum V95%iCTVtotal was 57% and 72% for XT and PT, respectively. Patient A and D showed minor inter-fractional changes and the minimum V95%iCTVtotal was >85%.

CONCLUSION

Large variability in dose to the lungs and heart was observed for both modalities. Inter-fractional anatomical changes led to larger target dose deterioration for XT than PT plans.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Haematology, Oncology, Infectious Diseases, Laboratory Medicine and Hospital Pharmacy (DOLS) > Clinic of Radiation Oncology

UniBE Contributor:

Weber, Damien Charles

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0167-8140

Publisher:

Elsevier

Language:

English

Submitter:

Basak Ginsbourger

Date Deposited:

27 Dec 2022 15:35

Last Modified:

27 Dec 2022 23:08

Publisher DOI:

10.1016/j.radonc.2022.04.029

PubMed ID:

35513132

Uncontrolled Keywords:

Anatomical changes Intensity modulated radiotherapy Oesophageal cancer Phase III trial Proton therapy Quality assurance Respiratory motion Treatment planning

BORIS DOI:

10.48350/176376

URI:

https://boris.unibe.ch/id/eprint/176376

Actions (login required)

Edit item Edit item
Provide Feedback