Temporal Trends and Contemporary Outcomes After Transcatheter Aortic Valve Replacement With Evolut PRO/PRO+ Self-Expanding Valves: Insights From the NEOPRO/NEOPRO-2 Registries.

Scotti, Andrea; Baggio, Sara; Pagnesi, Matteo; Barbanti, Marco; Adamo, Marianna; Eitan, Amnon; Estévez-Loureiro, Rodrigo; Veulemans, Verena; Toggweiler, Stefan; Mylotte, Darren; De Marco, Federico; Giannini, Francesco; Ferlini, Marco; Naber, Christoph K; Buono, Andrea; Schofer, Joachim; Rottbauer, Wolfgang; Van Mieghem, Nicolas M; Khogali, Saib; Taramasso, Maurizio; ... (2023). Temporal Trends and Contemporary Outcomes After Transcatheter Aortic Valve Replacement With Evolut PRO/PRO+ Self-Expanding Valves: Insights From the NEOPRO/NEOPRO-2 Registries. Circulation. Cardiovascular interventions, 16(1), e012538. American Heart Association 10.1161/CIRCINTERVENTIONS.122.012538

[img] Text
CIRCINTERVENTIONS.122.012538.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (999kB)

BACKGROUND

In recent years, transcatheter aortic valve replacement (TAVR) techniques and technology have continuously improved. Data regarding the impact of these advancements on outcomes in large real-world settings are still limited. The aim of this study was to investigate temporal trends and assess contemporary outcomes after TAVR with Evolut PRO/PRO+ supra-annular self-expanding valves.

METHODS

This study included patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries who underwent transfemoral TAVR with Evolut PRO/PRO+. Procedural dates (August 2017 through November 2021) were stratified in quartiles (Q) and used to investigate temporal trends in TAVR outcomes. Predischarge, 30-day Valve Academic Research Consortium-3 defined, and 1-year outcomes were evaluated.

RESULTS

In total, 1616 patients from 28 centers were included. Over time, patients had lower Society of Thoracic Surgeon-Predicted Risk of Mortality score (Q1-4, 4.1% [2.8-6.3%], 3.7% [2.6-5.3%], 3.3% [2.4-4.9%], 2.9% [2.2-4.3%]; P<0.001) and more moderate or heavy valve calcification (Q1-4, 80%, 80%, 82%, 88%; P=0.038). Overall Valve Academic Research Consortium-3 technical success was 94.1%, with 30-day and 1-year all-cause mortality of 2.4% and 10%, respectively. Throughout the study period, procedures were associated with higher rates of 30-day device success (Q1-4, 81.2%, 82.2%, 82.0%, 88.0%; Cochran-Armitage P=0.023) and early safety (Q1-4, 66.8%, 67.5%, 74.0%, 77.6%; Cochran-Armitage P<0.001), with fewer permanent pacemaker implantations (Q1-4: 15.3%, 20.0%, 12.1%, 11.6%; Cochran-Armitage P=0.023) and residual mild or greater paravalvular leaks (Q1-4, 50.4%, 42.1%, 36.5%, 35.8%; Cochran-Armitage P<0.001).

CONCLUSIONS

TAVR with Evolut PRO/PRO+ self-expanding valve is safe and effective. Despite the treatment of heavier calcified anatomies, procedural outcomes are improving over time with less need for pacemaker implantation and less significant paravalvular leaks.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

UniBE Contributor:

Pilgrim, Thomas

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1941-7632

Publisher:

American Heart Association

Language:

English

Submitter:

Pubmed Import

Date Deposited:

18 Jan 2023 13:44

Last Modified:

22 Jan 2023 02:16

Publisher DOI:

10.1161/CIRCINTERVENTIONS.122.012538

PubMed ID:

36649387

Uncontrolled Keywords:

aortic stenosis bioprosthesis heart valve prosthesis pacemaker transcatheter aortic valve replacement treatment outcome

BORIS DOI:

10.48350/177591

URI:

https://boris.unibe.ch/id/eprint/177591

Actions (login required)

Edit item Edit item
Provide Feedback