Incidence of premature battery depletion in subcutaneous cardioverter-defibrillator patients: insights from a multicenter registry.

Lüker, Jakob; Strik, Marc; Andrade, Jason G; Raymond-Paquin, Alexandre; Elrefai, Mohamed Hassan; Roberts, Paul R; Pérez, Óscar Cano; Kron, Jordana; Koneru, Jayanthi; Franqui-Rivera, Hilton; Sultan, Arian; Ernst, Angela; Schmitt, Jörn; Pott, Alexander; Veltmann, Christian; Srinivasan, Neil T; Collinson, Jason; van Stipdonk, Antonius M W; Linz, Dominik; Fluschnik, Nina; ... (2023). Incidence of premature battery depletion in subcutaneous cardioverter-defibrillator patients: insights from a multicenter registry. (In Press). Journal of interventional cardiac electrophysiology Springer 10.1007/s10840-023-01468-1

[img]
Preview
Text
s10840-023-01468-1.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (943kB) | Preview

BACKGROUND

The subcutaneous ICD established its role in the prevention of sudden cardiac death in recent years. The occurrence of premature battery depletion in a large subset of potentially affected devices has been a cause of concern. The incidence of premature battery depletion has not been studied systematically beyond manufacturer-reported data.

METHODS

Retrospective data and the most recent follow-up data on S-ICD devices from fourteen centers in Europe, the US, and Canada was studied. The incidence of generator removal or failure was reported to investigate the incidence of premature S-ICD battery depletion, defined as battery failure within 60 months or less.

RESULTS

Data from 1054 devices was analyzed. Premature battery depletion occurred in 3.5% of potentially affected devices over an observation period of 49 months.

CONCLUSIONS

The incidence of premature battery depletion of S-ICD potentially affected by a battery advisory was around 3.5% after 4 years in this study. Premature depletion occurred exclusively in devices under advisory. This is in line with the most recently published reports from the manufacturer.

TRIAL REGISTRATION

ClinicalTrials.gov Identifier: NCT04767516 .

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

UniBE Contributor:

Häberlin, Andreas David Heinrich

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1572-8595

Publisher:

Springer

Language:

English

Submitter:

Pubmed Import

Date Deposited:

19 Jan 2023 10:27

Last Modified:

19 Jan 2023 23:27

Publisher DOI:

10.1007/s10840-023-01468-1

PubMed ID:

36652082

Uncontrolled Keywords:

Advisory Implantable cardioverter-defibrillator Longevity Premature battery depletion Subcutaneous ICD

BORIS DOI:

10.48350/177672

URI:

https://boris.unibe.ch/id/eprint/177672