Chen, Stephen T; Buser, Daniel; Sculean, Anton; Belser, Urs C (2023). Complications and treatment errors in implant positioning in the aesthetic zone: Diagnosis and possible solutions. Periodontology 2000, 92(1), pp. 220-234. Wiley 10.1111/prd.12474
|
Text
Periodontology_2000_-_2023_-_Chen_-_Complications_and_treatment_errors_in_implant_positioning_in_the_aesthetic_zone_.pdf - Published Version Available under License Creative Commons: Attribution (CC-BY). Download (13MB) | Preview |
Incorrect implant positioning can lead to functional and aesthetic compromise. Implant positioning errors can occur in three dimensions: mesiodistal, corono-apical, and orofacial. Treatment solutions to manage adverse outcomes through positioning errors require an understanding of the underlying conditions and of those factors that may have led to the error being committed in the first place. These types of complications usually occur because of human factors. If errors do occur with adverse aesthetic outcomes, they are difficult and sometimes impossible to correct. Connective tissue grafts to reverse recession defects are only feasible in defined situations. The option to remove and replace the implant may be the only recourse, provided the removal process does not further compromise the site. Error in judgment by the clinician.
Item Type: |
Journal Article (Review Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > School of Dental Medicine > Department of Periodontology |
UniBE Contributor: |
Buser, Daniel Albin, Sculean, Anton |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
1600-0757 |
Publisher: |
Wiley |
Language: |
English |
Submitter: |
Pubmed Import |
Date Deposited: |
23 Jan 2023 11:04 |
Last Modified: |
16 Aug 2023 00:12 |
Publisher DOI: |
10.1111/prd.12474 |
PubMed ID: |
36683018 |
Uncontrolled Keywords: |
aesthetics complications dental implant malposition |
BORIS DOI: |
10.48350/177779 |
URI: |
https://boris.unibe.ch/id/eprint/177779 |