Precision of bone mechanoregulation assessment in humans using longitudinal high-resolution peripheral quantitative computed tomography in vivo.

Walle, Matthias; Whittier, Danielle E; Schenk, Denis; Atkins, Penny R; Blauth, Michael; Zysset, Philippe; Lippuner, Kurt; Müller, Ralph; Collins, Caitlyn J (2023). Precision of bone mechanoregulation assessment in humans using longitudinal high-resolution peripheral quantitative computed tomography in vivo. Bone, 172, p. 116780. Elsevier 10.1016/j.bone.2023.116780

[img]
Preview
Text
1-s2.0-S8756328223001138-main.pdf - Accepted Version
Available under License Creative Commons: Attribution (CC-BY).

Download (2MB) | Preview

Local mechanical stimuli in the bone microenvironment are essential for the homeostasis and adaptation of the skeleton, with evidence suggesting that disruption of the mechanically-driven bone remodelling process may lead to bone loss. Longitudinal clinical studies have shown the combined use of high-resolution peripheral quantitative computed tomography (HR-pQCT) and micro-finite element analysis can be used to measure load-driven bone remodelling in vivo; however, quantitative markers of bone mechanoregulation and the precision of these analyses methods have not been validated in human subjects. Therefore, this study utilised participants from two cohorts. A same-day cohort (n = 33) was used to develop a filtering strategy to minimise false detections of bone remodelling sites caused by noise and motion artefacts present in HR-pQCT scans. A longitudinal cohort (n = 19) was used to develop bone imaging markers of trabecular bone mechanoregulation and characterise the precision for detecting longitudinal changes in subjects. Specifically, we described local load-driven formation and resorption sites independently using patient-specific odds ratios (OR) and 99 % confidence intervals. Conditional probability curves were computed to link the mechanical environment to the remodelling events detected on the bone surface. To quantify overall mechanoregulation, we calculated a correct classification rate measuring the fraction of remodelling events correctly identified by the mechanical signal. Precision was calculated as root-mean-squared averages of the coefficient of variation (RMS-SD) of repeated measurements using scan-rescan pairs at baseline combined with a one-year follow-up scan. We found no significant mean difference (p < 0.01) between scan-rescan conditional probabilities. RMS-SD was 10.5 % for resorption odds, 6.3 % for formation odds, and 1.3 % for correct classification rates. Bone was most likely to be formed in high-strain and resorbed in low-strain regions for all participants, indicating a consistent, regulated response to mechanical stimuli. For each percent increase in strain, the likelihood of bone resorption decreased by 2.0 ± 0.2 %, and the likelihood of bone formation increased by 1.9 ± 0.2 %, totalling 38.3 ± 1.1 % of strain-driven remodelling events across the entire trabecular compartment. This work provides novel robust bone mechanoregulation markers and their precision for designing future clinical studies.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Orthopaedic, Plastic and Hand Surgery (DOPH) > Clinic of Osteoporosis
10 Strategic Research Centers > ARTORG Center for Biomedical Engineering Research > ARTORG Center - Musculoskeletal Biomechanics

UniBE Contributor:

Schenk, Denis Elia, Atkins, Penny, Zysset, Philippe, Lippuner, Kurt

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1873-2763

Publisher:

Elsevier

Language:

English

Submitter:

Pubmed Import

Date Deposited:

04 May 2023 10:24

Last Modified:

21 May 2023 00:19

Publisher DOI:

10.1016/j.bone.2023.116780

PubMed ID:

37137459

Uncontrolled Keywords:

Bone biomechanics High-resolution peripheral quantitative computed tomography Mechanobiology Mechanoregulation Micro-finite element analysis Repeatability Reproducibility

BORIS DOI:

10.48350/182289

URI:

https://boris.unibe.ch/id/eprint/182289

Actions (login required)

Edit item Edit item
Provide Feedback