Safety and Effectiveness of Pulsed Field Ablation to Treat Atrial Fibrillation: One-Year Outcomes From the MANIFEST-PF Registry.

Turagam, Mohit K; Neuzil, Petr; Schmidt, Boris; Reichlin, Tobias; Neven, Kars; Metzner, Andreas; Hansen, Jim; Blaauw, Yuri; Maury, Philippe; Arentz, Thomas; Sommer, Philipp; Anic, Ante; Anselme, Frederic; Boveda, Serge; Deneke, Tom; Willems, Stephan; van der Voort, Pepijn; Tilz, Roland; Funasako, Moritoshi; Scherr, Daniel; ... (2023). Safety and Effectiveness of Pulsed Field Ablation to Treat Atrial Fibrillation: One-Year Outcomes From the MANIFEST-PF Registry. Circulation, 148(1), pp. 35-46. American Heart Association 10.1161/CIRCULATIONAHA.123.064959

[img] Text
CIRCULATIONAHA.123.064959-1.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (797kB) | Request a copy

BACKGROUND

Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care.

METHODS

MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events.

RESULTS

At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients.

CONCLUSIONS

In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

UniBE Contributor:

Reichlin, Tobias Roman, Roten, Laurent, Kueffer, Thomas

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1524-4539

Publisher:

American Heart Association

Language:

English

Submitter:

Pubmed Import

Date Deposited:

19 May 2023 11:21

Last Modified:

04 Jul 2023 00:15

Publisher DOI:

10.1161/CIRCULATIONAHA.123.064959

PubMed ID:

37199171

Uncontrolled Keywords:

atrial fibrillation catheter ablation irreversible electroporation therapy treatment outcome

BORIS DOI:

10.48350/182675

URI:

https://boris.unibe.ch/id/eprint/182675

Actions (login required)

Edit item Edit item
Provide Feedback