OBJECTIVE

To compare the accuracy of three-dimensional (3D) printed patient-specific guide (PSG) with a freehand (FH) approach for radial osteotomies in ex vivo normal dogs.

STUDY DESIGN

Experimental study.

ANIMALS

Twenty four ex vivo thoracic limb pairs from normal beagle dogs.

METHODS

Computed tomography (CT) images were collected preoperatively and postoperatively. Three osteotomies tested (n = 8/group) were: (1) uniplanar 30° frontal plane wedge ostectomy, (2) oblique plane (30° frontal, 15° sagittal) wedge ostectomy, and (3) single oblique plane osteotomy (SOO, 30° frontal, 15° sagittal, and 30° external). Limb pairs were randomized to a 3D PSG or FH approach. The resultant osteotomies were compared with virtual target osteotomies by surface shape-matching postoperative to the preoperative radii.

RESULTS

The mean ± standard deviation osteotomy angle deviation for all 3D PSG osteotomies (2.8 ± 2.8°, range 0.11-14.1°) was less than for the FH osteotomies (6.4 ± 6.0°, range 0.03-29.7°). No differences were found for osteotomy location in any group. In total, 84% of 3D PSG osteotomies were within 5° deviance from the target compared to 50% of freehand osteotomies.

CONCLUSION

Three-dimensional PSG improved FH accuracy of osteotomy angle in select planes and the most complex osteotomy orientation in a normal ex vivo radial model.

CLINICAL SIGNIFICANCE

Three-dimensional PSGs provided more consistent accuracy, which was most notable in complex radial osteotomies. Future work is needed to investigate guided osteotomies in dogs with antebrachial bone deformities.

Item Type:

Journal Article (Original Article)

Division/Institute:

05 Veterinary Medicine > Department of Clinical Veterinary Medicine (DKV)
05 Veterinary Medicine > Department of Clinical Veterinary Medicine (DKV) > Small Animal Clinic > Small Animal Clinic, Surgery
05 Veterinary Medicine > Department of Clinical Veterinary Medicine (DKV) > Small Animal Clinic

UniBE Contributor:

Guevar, Julien Jean

Subjects:

600 Technology > 630 Agriculture

ISSN:

1532-950X

Publisher:

Wiley

Language:

English

Submitter:

Pubmed Import

Date Deposited:

14 Jun 2023 10:03

Last Modified:

16 Feb 2024 00:12

Publisher DOI:

10.1111/vsu.13968

PubMed ID:

37309843

BORIS DOI:

10.48350/183401

URI:

https://boris.unibe.ch/id/eprint/183401

Actions (login required)

Edit item Edit item
Provide Feedback