Viscoelastic properties of porcine lenses using optical coherence elastography and inverse finite element analysis.

Cabeza Gil, Iulen; Tahsini, Vahoura; Kling, Sabine (2023). Viscoelastic properties of porcine lenses using optical coherence elastography and inverse finite element analysis. Experimental eye research, 233(109558), p. 109558. Elsevier 10.1016/j.exer.2023.109558

[img] Text
1-s2.0-S0014483523001793-main.pdf - Accepted Version
Restricted to registered users only until 27 June 2024.
Available under License Publisher holds Copyright.

Download (1MB) | Request a copy

The mechanical properties of the crystalline lens are crucial in determining the changes in lens shape that occur during the accommodation process and are also a major factor in the development of the two most prevalent age-related diseases of the lens, presbyopia and cataracts. However, a comprehensive understanding of these properties is currently lacking. Previous methods for characterizing the mechanical properties of the lens have been limited by the amount of data that could be collected during each test and the lack of complex material modeling. These limitations were mainly caused by the lack of imaging techniques that can provide data for the entire crystalline lens and the need for more complex models to describe the non-linear behavior of the lens. To address these issues, we characterized the mechanical properties of 13 porcine lenses during an ex vivo micro-controlled-displacement compression experiment using optical coherence elastography (OCE) and inverse finite element analysis (iFEA). OCE allowed us to quantify the internal strain distribution of the lens and differentiate between the different parts of the lens, while iFEA enabled us to implement an advanced material model to characterize the viscoelasticity of the lens nucleus and the relative stiffness gradient in the lens. Our findings revealed a pronounced and rapid viscoelastic behavior in the lens nucleus (g1 = 0.39 ± 0.13, τ1 = 5.01 ± 2.31 s) and identified the lens nucleus as the stiffest region, with a stiffness 4.42 ± 1.20 times greater than the anterior cortex and 3.47 ± 0.82 times greater than the posterior cortex. However, due to the complex nature of lens properties, it may be necessary to employ multiple tests simultaneously for a more comprehensive understanding of the crystalline lens.

Item Type:

Journal Article (Original Article)

Division/Institute:

10 Strategic Research Centers > ARTORG Center for Biomedical Engineering Research > ARTORG Center - AI in Medical Imaging Laboratory
10 Strategic Research Centers > ARTORG Center for Biomedical Engineering Research

UniBE Contributor:

Tahsini, Vahoura, Kling, Sabine

Subjects:

600 Technology > 610 Medicine & health
500 Science > 570 Life sciences; biology

ISSN:

0014-4835

Publisher:

Elsevier

Language:

English

Submitter:

Pubmed Import

Date Deposited:

03 Jul 2023 10:22

Last Modified:

24 Jul 2023 00:16

Publisher DOI:

10.1016/j.exer.2023.109558

PubMed ID:

37385534

BORIS DOI:

10.48350/184280

URI:

https://boris.unibe.ch/id/eprint/184280

Actions (login required)

Edit item Edit item
Provide Feedback