Schlaeger, Sarah; Shit, Suprosanna; Eichinger, Paul; Hamann, Marco; Opfer, Roland; Krüger, Julia; Dieckmeyer, Michael; Schön, Simon; Mühlau, Mark; Zimmer, Claus; Kirschke, Jan S; Wiestler, Benedikt; Hedderich, Dennis M (2023). AI-based detection of contrast-enhancing MRI lesions in patients with multiple sclerosis. Insights into imaging, 14(1), p. 123. Springer 10.1186/s13244-023-01460-3
|
Text
s13244-023-01460-3.pdf - Published Version Available under License Creative Commons: Attribution (CC-BY). Download (1MB) | Preview |
BACKGROUND
Contrast-enhancing (CE) lesions are an important finding on brain magnetic resonance imaging (MRI) in patients with multiple sclerosis (MS) but can be missed easily. Automated solutions for reliable CE lesion detection are emerging; however, independent validation of artificial intelligence (AI) tools in the clinical routine is still rare.
METHODS
A three-dimensional convolutional neural network for CE lesion segmentation was trained externally on 1488 datasets of 934 MS patients from 81 scanners using concatenated information from FLAIR and T1-weighted post-contrast imaging. This externally trained model was tested on an independent dataset comprising 504 T1-weighted post-contrast and FLAIR image datasets of MS patients from clinical routine. Two neuroradiologists (R1, R2) labeled CE lesions for gold standard definition in the clinical test dataset. The algorithmic output was evaluated on both patient- and lesion-level.
RESULTS
On a patient-level, recall, specificity, precision, and accuracy of the AI tool to predict patients with CE lesions were 0.75, 0.99, 0.91, and 0.96. The agreement between the AI tool and both readers was within the range of inter-rater agreement (Cohen's kappa; AI vs. R1: 0.69; AI vs. R2: 0.76; R1 vs. R2: 0.76). On a lesion-level, false negative lesions were predominately found in infratentorial location, significantly smaller, and at lower contrast than true positive lesions (p < 0.05).
CONCLUSIONS
AI-based identification of CE lesions on brain MRI is feasible, approaching human reader performance in independent clinical data and might be of help as a second reader in the neuroradiological assessment of active inflammation in MS patients.
CRITICAL RELEVANCE STATEMENT
Al-based detection of contrast-enhancing multiple sclerosis lesions approaches human reader performance, but careful visual inspection is still needed, especially for infratentorial, small and low-contrast lesions.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic, Interventional and Paediatric Radiology |
UniBE Contributor: |
Dieckmeyer, Michael |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
1869-4101 |
Publisher: |
Springer |
Language: |
English |
Submitter: |
Pubmed Import |
Date Deposited: |
17 Jul 2023 08:35 |
Last Modified: |
23 Jul 2023 02:33 |
Publisher DOI: |
10.1186/s13244-023-01460-3 |
PubMed ID: |
37454342 |
Uncontrolled Keywords: |
Artificial intelligence Clinical decision support Contrast-enhancing lesions Magnetic resonance imaging Multiple sclerosis |
BORIS DOI: |
10.48350/184868 |
URI: |
https://boris.unibe.ch/id/eprint/184868 |