Hip Morphology on Post-Reduction MRI Predicts Residual Dysplasia 10 Years After Open or Closed Reduction.

Schmaranzer, Florian; Justo, Pedro; Kallini, Jennifer R; Ferrer, Mariana G; Miller, Patricia; Bixby, Sarah D; Novais, Eduardo N (2024). Hip Morphology on Post-Reduction MRI Predicts Residual Dysplasia 10 Years After Open or Closed Reduction. The journal of bone & joint surgery. American volume, 106(2), pp. 110-119. Wolters Kluwer 10.2106/JBJS.23.00333

[img] Text
hip_morphology_on_post_reduction_mri_predicts.954.pdf - Published Version
Restricted to registered users only
Available under License Publisher holds Copyright.

Download (1MB) | Request a copy

BACKGROUND

There is limited evidence supporting the value of morphological parameters on post-reduction magnetic resonance imaging (MRI) to predict long-term residual acetabular dysplasia (RAD) after closed or open reduction for the treatment of developmental dysplasia of the hip (DDH).

METHODS

We performed a retrospective study of 42 patients (47 hips) undergoing open or closed reduction with a minimum 10 years of follow-up; 39 (83%) of the hips were in female patients, and the median age at reduction was 6.3 months (interquartile range [IQR], 3.3 to 8.9 months). RAD was defined as additional surgery with an acetabular index >2 standard deviations above the age- and sex-specific population-based mean value or Severin classification grade of >2 at last follow-up. Acetabular version and depth-width ratio, coronal and axial femoroacetabular distance, cartilaginous and osseous acetabular indices, transverse ligament thickness, and the thickness of the medial and lateral (limbus) acetabular cartilage were measured on post-reduction MRI.

RESULTS

At the time of final follow-up, 24 (51%) of the hips had no RAD; 23 (49%) reached a failure end point at a median of 11.4 years (IQR, 7.6 to 15.4 years). Most post-reduction MRI measurements, with the exception of the cartilaginous acetabular index, revealed a significant distinction between the group with RAD and the group with no RAD when mean values were compared. The coronal femoroacetabular distance (area under the receiver operating characteristic curve [AUC], 0.95; 95% confidence interval [CI], 0.90 to 1.00), with a 5-mm cutoff, and limbus thickness (AUC, 0.91; 95% CI, 0.83 to 0.99), with a 4-mm cutoff, had the highest discriminatory ability. A 5-mm cutoff for the coronal femoroacetabular distance produced 96% sensitivity (95% CI, 78% to 100%), 83% specificity (95% CI, 63% to 95%), 85% positive predictive value (95% CI, 65% to 96%), and 95% negative predictive value (95% CI, 76% to 100%). A 4-mm cutoff for limbus thickness had 96% sensitivity (95% CI, 78% to 100%), 63% specificity (95% CI, 41% to 81%), 71% positive predictive value (95% CI, 52% to 86%), and 94% negative predictive value (95% CI, 70% to 100%).

CONCLUSIONS

Coronal femoroacetabular distance, a quantitative metric assessing a reduction's concentricity, and limbus thickness, a quantitative metric assessing the acetabulum's cartilaginous component, help to predict hips that will have RAD in the long term after closed or open reduction.

LEVEL OF EVIDENCE

Diagnostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Radiology, Neuroradiology and Nuclear Medicine (DRNN) > Institute of Diagnostic, Interventional and Paediatric Radiology

UniBE Contributor:

Schmaranzer, Florian

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1535-1386

Publisher:

Wolters Kluwer

Language:

English

Submitter:

Pubmed Import

Date Deposited:

23 Nov 2023 13:15

Last Modified:

18 Jan 2024 00:15

Publisher DOI:

10.2106/JBJS.23.00333

PubMed ID:

37992184

BORIS DOI:

10.48350/189293

URI:

https://boris.unibe.ch/id/eprint/189293

Actions (login required)

Edit item Edit item
Provide Feedback