Schaefer, Christine A; Nigg, Claudio R.; Hill, James O; Brink, Lois A; Browning, Raymond C (2014). Establishing and Evaluating Wrist Cutpoints for the GENEActiv Accelerometer in Youth. Medicine and science in sports and exercise, 46(4), pp. 826-833. Lippincott Williams & Wilkins 10.1249/MSS.0000000000000150
Text
establishing_and_evaluating_wrist_cutpoints_for.24.pdf - Published Version Restricted to registered users only Available under License Publisher holds Copyright. Download (190kB) |
Purpose: This study aimed to establish physical activity (PA) intensity cutpoints for a wrist-mounted GENEActiv accelerometer (ACC) in elementary school-age children. A second purpose was to apply cutpoints to a free-living sample and examine the duration of PA based on continuous 1-s epochs.
Methods: Metabolic and ACC data were collected during nine typical activities in 24 children age 6-11 yr. Measured VO2 values were divided by Schofield-estimated resting values to determine METs. ACC data were collected at 75 Hz, band pass filtered, and averaged over each 1-s interval. Receiver operator characteristic curves were used to establish cutpoints at sedentary (≤ 1.5 METs), light (1.6-2.99 METs), moderate (3.0-5.99 METs), and vigorous (≥ 6 METs) activities. These cutpoints were applied to a free-living independent data set to quantify the amount of moderate-vigorous PA (MVPA) and to examine how bout length (1, 2, 3, 5, 10, 15, and 60 s) affected the accumulation of MVPA.
Results: Receiver operator characteristic yielded areas under the curve of 0.956, 0.946, and 0.940 for sedentary, moderate, and vigorous intensities, respectively. Cutpoints for sedentary, moderate, and vigorous intensities were 0.190 g, 0.314 g, and 0.998 g, respectively. Intensity classification accuracies ranged from 27.6% (light) to 88.7% (vigorous) when cutpoints were applied to the calibration data. When applied to free-living data (n = 47 children age 6-11 yr), estimated daily MVPA was 308 min and decreased to 14.3 min when only including 1-min periods of continuous MVPA.
Conclusions: Cutpoints that quantify movements associated with moderate-vigorous intensity, when applied to a laboratory protocol, result in large amounts of accumulated MVPA using the 1-s epoch compared to prior studies, highlighting the need for representative calibration activities and free-living validation of cutpoints and epoch length selection.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
07 Faculty of Human Sciences > Institute of Sport Science (ISPW) |
UniBE Contributor: |
Nigg, Claudio Renato |
Subjects: |
700 Arts > 790 Sports, games & entertainment |
ISSN: |
0195-9131 |
Publisher: |
Lippincott Williams & Wilkins |
Language: |
English |
Submitter: |
Claudio Renato Nigg |
Date Deposited: |
20 Jun 2024 09:23 |
Last Modified: |
01 Jul 2024 16:14 |
Publisher DOI: |
10.1249/MSS.0000000000000150 |
PubMed ID: |
24121241 |
BORIS DOI: |
10.48350/193318 |
URI: |
https://boris.unibe.ch/id/eprint/193318 |