Effects of tricuspid transcatheter edge-to-edge repair on tricuspid annulus diameter - Data from the TriValve registry.

Russo, Giulio; Hahn, Rebecca T; Alessandrini, Hannes; Andreas, Martin; Badano, Luigi P; Braun, Daniel; Connelly, Kim A; Denti, Paolo; Estevez-Loureiro, Rodrigo; Fam, Neil; Gavazzoni, Mara; Hausleiter, Joerg; Himbert, Dominique; Kalbacher, Daniel; Latib, Azeem; Lubos, Edith; Ludwig, Sebastian; Lurz, Philipp; Monivas, Vanessa; Nickenig, Georg; ... (2024). Effects of tricuspid transcatheter edge-to-edge repair on tricuspid annulus diameter - Data from the TriValve registry. International journal of cardiology, 405(131934), p. 131934. Elsevier 10.1016/j.ijcard.2024.131934

[img] Text
1-s2.0-S0167527324004522-main.pdf - Accepted Version
Restricted to registered users only until 2 March 2025.
Available under License Publisher holds Copyright.

Download (4MB)

AIMS

T-TEER is an effective therapy for the treatment of tricuspid regurgitation (TR). However, the effects of leaflets clipping on tricuspid valve annulus (TA) have not been investigated in detail. The aim of this study is to investigate the effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on TA diameter.

METHODS AND RESULTS

The TriValve registry (Transcatheter Tricuspid Valve Therapies, NCT03416166) collected 556 patients from 22 European and North American centres undergoing transcatheter tricuspid valve interventions from 2016 to 2022. Patients undergoing T-TEER with available pre- and post-procedural data on TA diameter measured in the apical 4-chamber view on transthoracic echocardiography were selected for this study. Primary end-point was the reduction of TA diameter after T-TEER. A total of 186 patients were included in the study. In 115 patients (62%) TA diameter was reduced by at least 1 mm as compared to baseline. A significant reduction of TA dimension was observed following T-TEER (mean 2.3 mm [from pre-procedural diameter 46.7 mm to post-procedural diameter 44.4 mm], p < 0.001). In particular, the greatest reduction was observed in those with T-TEER in antero-septal commissure (mean 2.7 mm [from 47.1 mm to 44.4 mm], p < 0.001) as compared to those combining both antero-septal and postero-septal commissures (mean 1.4, from 46.0 mm to 44.6 mm, P = 0.06). A significant reduction of TA dimension was recorded in patients with 1 or 2 clips implanted but not in those patients with ≥3 clips implanted.

CONCLUSIONS

In almost two third of patients T-TEER reduces TA diameter in addition to leaflet approximation.

CONDENSED ABSTRACT

The effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on tricuspid valve annulus (TA) have not been studied in details. This study investigates TA diameter as measured in apical 4-chamber view on transthoracic echocardiography before and after T-TEER. A total of 186 patients from the TriValve registry were included in the study. The study results show that 62% of patients have a TA reduction after T-TEER, especially in those receiving 1 or 2 clips in the antero-septal commissure. These suggest that T-TEER reduces tricuspid regurgitation not only by approximation of leaflets, but also by TA diameter reduction.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > Department of Cardiovascular Disorders (DHGE) > Clinic of Cardiology

UniBE Contributor:

Praz, Fabien Daniel, Windecker, Stephan

Subjects:

600 Technology > 610 Medicine & health

ISSN:

0167-5273

Publisher:

Elsevier

Language:

English

Submitter:

Pubmed Import

Date Deposited:

05 Mar 2024 10:38

Last Modified:

28 Apr 2024 00:15

Publisher DOI:

10.1016/j.ijcard.2024.131934

PubMed ID:

38437953

Uncontrolled Keywords:

Transcatheter edge-to-edge repair Transcatheter tricuspid valve interventions Tricuspid annulus Tricuspid regurgitation

BORIS DOI:

10.48350/193787

URI:

https://boris.unibe.ch/id/eprint/193787

Actions (login required)

Edit item Edit item
Provide Feedback