Digital setup accuracy for moderate crowding correction with fixed orthodontic appliances: a prospective study.

Kusaibati, Abdalrahman Mohieddin; Sultan, Kinda; Hajeer, Mohammad Younis; Gkantidis, Nikolaos (2024). Digital setup accuracy for moderate crowding correction with fixed orthodontic appliances: a prospective study. Progress in orthodontics, 25(13) Springer 10.1186/s40510-024-00513-7

[img]
Preview
Text
s40510-024-00513-7.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (3MB) | Preview

OBJECTIVES

To evaluate the accuracy of a semi-automatic 3D digital setup process in predicting the orthodontic treatment outcome achieved by labial fixed appliances.

SUBJECTS AND METHODS

Twenty-five adult patients (18 to 24 years old) with class I malocclusion and moderate crowding were prospectively enrolled and received treatment on both jaws through the straight-wire technique. Prior to treatment commencement, a semi-automatic digital setup simulating the predicted treatment outcome was performed for each patient through Orthoanalyzer software (3Shape®, Copenhagen, Denmark) to obtain the prediction model. This was compared to the final outcome model through 3D superimposition methods. Metric variables and inspection of color-coded distance maps were used to detect how accurately the digital setup predicts the actual treatment outcome.

RESULTS

The mean absolute distances (MAD) between the superimposed dental arches of the predicted and the final models were: 0.77 ± 0.13 mm following superimposition on the palate, 0.52 ± 0.06 mm following superimposition on the maxillary dental arch, and 0.55 ± 0.15 mm following superimposition on the mandibular dental arch. The MAD at the palatal reference area was 0.09 ± 0.04 mm. Visualization of color-coded distance maps indicated that the digital setup accurately predicted the final teeth position in a few cases. Almost half of the cases had posteriorly wider upper and lower dental arches and palatally/lingually positioned or inclined anterior teeth, whereas the rest still showed errors within 2-3 mm, distributed over the entire dental arches with no distinct pattern.

CONCLUSIONS

The accuracy of semi-automatic prediction of the labial fixed appliance treatment outcome in Class I cases with moderate crowding is not yet sufficient. While average measures showed deviations less than 1 mm, examination of individual color-coded distance maps revealed significant disparities between the simulated and the actual results.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Orthodontics

UniBE Contributor:

Gkantidis, Nikolaos

Subjects:

600 Technology > 610 Medicine & health

ISSN:

2196-1042

Publisher:

Springer

Language:

English

Submitter:

Pubmed Import

Date Deposited:

08 Apr 2024 10:06

Last Modified:

08 Apr 2024 10:15

Publisher DOI:

10.1186/s40510-024-00513-7

PubMed ID:

38584176

Uncontrolled Keywords:

Accuracy Computer simulation Dental model Fixed orthodontic appliances Three-dimensional imaging Tooth movement technique

BORIS DOI:

10.48350/195741

URI:

https://boris.unibe.ch/id/eprint/195741

Actions (login required)

Edit item Edit item
Provide Feedback