Dimensional Stability of Additively Manufactured Dentate Maxillary Diagnostic Casts in Biobased Model Resin.

Demirel, Münir; Diken Türksayar, Almira Ada; Petersmann, Sandra; Spintzyk, Sebastian; Donmez, Mustafa Borga (2024). Dimensional Stability of Additively Manufactured Dentate Maxillary Diagnostic Casts in Biobased Model Resin. Materials, 17(9) Molecular Diversity Preservation International MDPI 10.3390/ma17092128

[img]
Preview
Text
materials-17-02128.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (3MB) | Preview

This study aimed to evaluate the dimensional stability of maxillary diagnostic casts fabricated from a biobased model resin, which consists of 50% renewable raw materials for sustainable production, a model resin, and stone, over one month. A master maxillary stone cast was digitized with a laboratory scanner to generate a reference file. This master cast was also scanned with an intraoral scanner to additively manufacture casts with a biobased model resin (BAM) and a model resin (AM). Polyvinylsiloxane impressions of the master cast were also made and poured in type III stone (CV) (n = 8). The same laboratory scanner was used to digitize each model one day (T0), 1 week (T1), 2 weeks (T2), 3 weeks (T3), and 4 weeks (T4) after fabrication. Deviations from the reference file were calculated with an analysis software and analyzed with generalized linear model analysis (α = 0.05). The interaction between the material and the time point affected measured deviations (p < 0.001). Regardless of the time point, CV had the lowest and AM had the highest deviations (p < 0.001). BAM mostly had lower deviations at T0 and mostly had higher deviations at T4 (p ≤ 0.011). AM had the highest deviations at T4 and then at T3, whereas it had the lowest deviations at T0 (p ≤ 0.002). The measured deviations of CV increased after each time point (p < 0.001). BAM casts had deviations within the previously reported clinically acceptable thresholds over one month and had acceptable dimensional stability. Therefore, tested biobased resin may be a viable alternative for the sustainable manufacturing of maxillary diagnostic casts that are to be used clinically.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine

UniBE Contributor:

Dönmez, Mustafa-Borga

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1996-1944

Publisher:

Molecular Diversity Preservation International MDPI

Language:

English

Submitter:

Pubmed Import

Date Deposited:

13 May 2024 10:40

Last Modified:

14 May 2024 15:54

Publisher DOI:

10.3390/ma17092128

PubMed ID:

38730934

Uncontrolled Keywords:

additive manufacturing biobased model resin dental cast dimensional stability sustainable manufacturing

BORIS DOI:

10.48350/196711

URI:

https://boris.unibe.ch/id/eprint/196711

Actions (login required)

Edit item Edit item
Provide Feedback