Demirel, Münir; Diken Türksayar, Almira Ada; Petersmann, Sandra; Spintzyk, Sebastian; Donmez, Mustafa Borga (2024). Dimensional Stability of Additively Manufactured Dentate Maxillary Diagnostic Casts in Biobased Model Resin. Materials, 17(9) MDPI 10.3390/ma17092128
|
Text
materials-17-02128.pdf - Published Version Available under License Creative Commons: Attribution (CC-BY). Download (3MB) | Preview |
This study aimed to evaluate the dimensional stability of maxillary diagnostic casts fabricated from a biobased model resin, which consists of 50% renewable raw materials for sustainable production, a model resin, and stone, over one month. A master maxillary stone cast was digitized with a laboratory scanner to generate a reference file. This master cast was also scanned with an intraoral scanner to additively manufacture casts with a biobased model resin (BAM) and a model resin (AM). Polyvinylsiloxane impressions of the master cast were also made and poured in type III stone (CV) (n = 8). The same laboratory scanner was used to digitize each model one day (T0), 1 week (T1), 2 weeks (T2), 3 weeks (T3), and 4 weeks (T4) after fabrication. Deviations from the reference file were calculated with an analysis software and analyzed with generalized linear model analysis (α = 0.05). The interaction between the material and the time point affected measured deviations (p < 0.001). Regardless of the time point, CV had the lowest and AM had the highest deviations (p < 0.001). BAM mostly had lower deviations at T0 and mostly had higher deviations at T4 (p ≤ 0.011). AM had the highest deviations at T4 and then at T3, whereas it had the lowest deviations at T0 (p ≤ 0.002). The measured deviations of CV increased after each time point (p < 0.001). BAM casts had deviations within the previously reported clinically acceptable thresholds over one month and had acceptable dimensional stability. Therefore, tested biobased resin may be a viable alternative for the sustainable manufacturing of maxillary diagnostic casts that are to be used clinically.
Item Type: |
Journal Article (Original Article) |
---|---|
Division/Institute: |
04 Faculty of Medicine > School of Dental Medicine |
UniBE Contributor: |
Dönmez, Mustafa-Borga |
Subjects: |
600 Technology > 610 Medicine & health |
ISSN: |
1996-1944 |
Publisher: |
MDPI |
Language: |
English |
Submitter: |
Pubmed Import |
Date Deposited: |
13 May 2024 10:40 |
Last Modified: |
07 Aug 2024 15:44 |
Publisher DOI: |
10.3390/ma17092128 |
PubMed ID: |
38730934 |
Uncontrolled Keywords: |
additive manufacturing biobased model resin dental cast dimensional stability sustainable manufacturing |
BORIS DOI: |
10.48350/196711 |
URI: |
https://boris.unibe.ch/id/eprint/196711 |