Clinical, radiographic, and aesthetic outcomes at two narrow-diameter implants to replace congenital missing maxillary lateral incisors: A 3-year prospective, clinical study.

Roccuzzo, Andrea; Imber, Jean-Claude; Lempert, Jakob; Jensen, Simon Storgård (2024). Clinical, radiographic, and aesthetic outcomes at two narrow-diameter implants to replace congenital missing maxillary lateral incisors: A 3-year prospective, clinical study. Clinical implant dentistry and related research, 26(4), pp. 777-786. Blackwell 10.1111/cid.13339

[img]
Preview
Text
Clin_Implant_Dent_Rel_Res_-_2024_-_Roccuzzo_-_Clinical_radiographic_and_aesthetic_outcomes_at_two_narrow_diameter.pdf - Published Version
Available under License Creative Commons: Attribution (CC-BY).

Download (1MB) | Preview

INTRODUCTION

To present the 3-year clinical, radiographic, and aesthetic outcomes in patients with congenitally missing lateral incisors rehabilitated with two narrow-diameter implants (NDIs).

METHODS

The original population consisted of 100 patients rehabilitated with a cement-retained bi-layered zirconia single-unit crown supported by either a Ø2.9 mm (Test) or a Ø3.3 mm (Control) NDI (n = 50). At the 1- and 3-year follow-up (T2, T3), implant survival rate, crestal bone level (CBL) changes, biological, and technical complications were recorded, while the assessment of the aesthetic outcomes was performed using the Copenhagen Index Score.

RESULTS

Seventy-four patients Ø2.9 mm (n = 39) or Ø3.3 mm (n = 35) reached T3, as 24 patients were lost to follow-up and 1 implant (Ø3.3 mm) was removed. Throughout the observation period, minimal CBL changes (i.e., <1 mm) were detected between groups. Despite the positive aesthetic scores recorded (i.e., 1-2), at T3 20% of patients rehabilitated with a Ø3.3 mm versus 2.6% of patients Ø2.9 mm displayed an alveolar process deficiency (Score 3). No additional technical and/or mechanical complications were recorded between T2 and T3. Tooth vitality was maintained in all neighboring teeth. Peri-implant probing depths and plaque scores remained low in both groups (p > 0.05).

CONCLUSION

The use of 2.9 or 3.3 diameter implants showed comparable favorable mid-term results in terms of survival rate, CBL, and aesthetic outcomes. Hence, clinicians should rely on the use of such NDIs when replacing maxillary lateral incisors.

Item Type:

Journal Article (Original Article)

Division/Institute:

04 Faculty of Medicine > School of Dental Medicine > Department of Periodontology

UniBE Contributor:

Roccuzzo, Andrea

Subjects:

600 Technology > 610 Medicine & health

ISSN:

1523-0899

Publisher:

Blackwell

Language:

English

Submitter:

Pubmed Import

Date Deposited:

12 Jun 2024 09:41

Last Modified:

09 Aug 2024 00:14

Publisher DOI:

10.1111/cid.13339

PubMed ID:

38863078

Uncontrolled Keywords:

clinical research clinical trials dental implants patient centered outcomes prosthodontics

BORIS DOI:

10.48350/197773

URI:

https://boris.unibe.ch/id/eprint/197773

Actions (login required)

Edit item Edit item
Provide Feedback